Interface Board Diagnostic Charts - Frymaster PRO series Service & Parts Manual

Table of Contents

Advertisement

1.10 Interface Board Diagnostic Chart
The following diagram and charts provide ten quick system checks that can be performed using only
a multimeter.
Diagostic LEDs
3
6
9
12
15
K1
K2
Left
Left
Heat
Latch
Relay
Relay
4
10
7
1
11
8
5
2
12
9
6
3
Test Points
J1 Left J2 Right
Meter Setting
12 VAC Power
24 VAC Power
*Probe Resistance (RH)
*Probe Resistance (LH)
Hi-Limit Continuity (RH)
Hi-Limit Continuity (LH)
Latch Contactor Coil (RH)
Latch Contactor Coil (LH)
Heat Contactor Coil (RH)
Heat Contactor Coil (LH)
* Disconnect 15-Pin harness from the computer/controller before testing the probe circuit.
1
2
5
4
8
7
11
10
13
14
K3
K4
Right
Right
Heat
Latch
Relay
Relay
7
4
1
10
5
11
8
2
6
12
9
3
Test
50 VAC Scale
50 VAC Scale
R X 1000 OHMS
R X 1000 OHMS
R X 1 OHMS
R X 1 OHMS
R X 1 OHMS
R X 1 OHMS
R X 1 OHMS
R X 1 OHMS
Diagnostic LED Legend
CMP indicates power from 12V transformer
24
indicates power from 24V transformer
HI
(RH) indicates output (closed) from right latch
relay
HI
(LH) indicates output (closed) from left latch
relay
HT
(RH) indicates output from right heat relay
HT
(LH) indicates output from left heat relay
AL
(RH) indicates output (open) from right latch
relay
AL
(LH) indicates output (open) from left latch
relay
Modular Basket Lift Schematic
H
5
1 or 4
Basket Lift
Relay
3
To computer/controller via
interface board
Pin
1 of J2
3 of J2
2 of J2
Chassis
11 of J2
12 of J2
3 of J1
2 of J1
7 of J2
4 of J2
4 of J1
7 of J1
8 of J2
Chassis
5 of J1
Chassis
9 of J2
Chassis
6 of J1
Chassis
1-15
Normally Open Upper-limit
Microswitch
M
Normally Closed Lower-limit
Microswitch
Pin
Results
12-16 VAC
24-30 VAC
See Chart
See Chart
0 - OHMS
0 - OHMS
3-10 OHMS
3-10 OHMS
18-25 OHMS
18-25 OHMS
N
6

Advertisement

Table of Contents
loading