5.3
The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. To allow the unit to work with this type of gas, perform the
same operations described in paragraph "5.2 Regulation for LPG", but
choose the nozzles and regulate the primary air for natural gas, as
shown in the following table and in paragraph "5.5 Regulation of
primary air". After the regulations have been carried out, restore the
seals with sealing wax or equivalent material.
Burner
Auxiliary (1)
Semirapid (2)
Rapid (3)
Rapid large (4)
Fish pan (7)
Ultra rapid (5)
Double
Internal
crown
External
(6)
5.4
To allow the unit to work with this type of gas, perform the same
operations described in paragraph "5.2 Regulation for LPG", but
choose the nozzles and regulate the primary air for town gas, as shown
in the following table and in paragraph "5.5 Regulation of primary air".
Attention! Only units with safety valves can be used with town gas
G110.
Burner
Auxiliary (1)
Semirapid (2)
Rapid (3)
Rapid large (4)
Fish pan (7)
Ultra rapid (5)
Double crown
Internal
(6)
External
Instructions for the installer

Regulation for natural gas

Rated heating
capacity
1.05
1.65
2.55
3.1
2.0
3.3
1.05
3.9
Regulation for town gas
Rated heating
capacity
1.05
1.65
2.55
3.1
2
3.3
1.05
3.9
Natural gas – G20 20 mbar
Nozzle diameter
1/100 mm
73
92
115
126
100
130
73
140
Town Gas 110 - 8 mbar
Nozzle diameter
1/100 mm
132
165
210
240
190
250
132
290
Reduced flowrate
(W)
380
380
650
750
750
1200
380
1200
Reduced flowrate
(W)
380
380
650
750
750
1200
380
1200
31

Advertisement