Regulation For Natural Gas - Smeg GCO90XG Instructions For Installation And Use Manual

Smeg range instructions for installation and use
Table of Contents

Advertisement

5.3 Regulation for natural gas

The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. To allow the unit to work with this type of gas, perform the same
operations described in paragraph "5.2 Regulation for LPG", but choose
the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph "5.4 Regulation of primary air". After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.
Burner
Auxiliary (1)
Semi-rapid (2)
Rapid (3)
Ultra rapid (4)
Double crown
internal (5)
external (5)
Fish pan (6)
5.4 Regulation for town gas
To allow the unit to work with this type of gas, perform the same
operations described in paragraph "5.2 Regulation for LPG", but choose
the nozzles and regulate the primary air for town gas, as shown in the
following table and in paragraph "5.5 Regulation of primary air".
Attention! Only units with safety valves can be used with town gas
G110.
Bruciatore
Ausiliario (1)
Semirapido (2)
Rapido (3)
Ultra rapido (4)
Doppia corona
interna (5)
esterna (5)
Pescera (6)
I valori relativi al gas città si riferiscono agli apparecchi della categoria III 1a2H3+.
32
Instructions for the installer
Rated
heating
capacity
(kW)
1.05
1.65
3.1
3.3
1.05
3.9
2.9
Portata
termica
nominale
(kW)
1.05
1.65
3.1
3.3
1.05
3.9
2.9
Natural gas – G20 20 mbar
Nozzle diameter
1/100 mm
73
92
126
130
73
140
123
Gas città – G110 8 mbar
Diametro ugello
1/100 mm
132
165
240
250
132
290
230
Reduced flowrate
(W)
380
380
750
1200
380
1200
800
Portata ridotta
(W)
380
380
800
1200
380
1200
800