General Information; A/C Application Table; Safety Precautions And Warnings - Chrysler Stratus RHD 1999 Electronic Service Manual

Table of Contents

Advertisement

24 - 2
HEATING AND AIR CONDITIONING
GENERAL INFORMATION (Continued)

SAFETY PRECAUTIONS AND WARNINGS

WARNING: WEAR EYE PROTECTION WHEN SER-
VICING THE AIR CONDITIONING REFRIGERANT
SYSTEM. SERIOUS EYE INJURY CAN RESULT
FROM EYE CONTACT WITH REFRIGERANT. IF EYE
CONTACT IS MADE, SEEK MEDICAL ATTENTION
IMMEDIATELY.
DO NOT EXPOSE REFRIGERANT TO OPEN
FLAME. POISONOUS GAS IS CREATED WHEN
REFRIGERANT IS BURNED. AN ELECTRONIC TYPE
LEAK DETECTOR IS RECOMMENDED.
LARGE AMOUNTS OF REFRIGERANT RELEASED
IN A CLOSED WORK AREA WILL DISPLACE THE
OXYGEN AND CAUSE SUFFOCATION.
THE EVAPORATION RATE OF REFRIGERANT AT
AVERAGE
TEMPERATURE
EXTREMELY HIGH. AS A RESULT, ANYTHING THAT
COMES IN CONTACT WITH THE REFRIGERANT
WILL FREEZE. ALWAYS PROTECT SKIN OR DELI-
CATE OBJECTS FROM DIRECT CONTACT WITH
REFRIGERANT. R-134a SERVICE EQUIPMENT OR
VEHICLE A/C SYSTEM SHOULD NOT BE PRES-
SURE TESTED OR LEAK TESTED WITH COM-
PRESSED AIR.
SOME MIXTURES OF AIR and R-134a HAVE BEEN
SHOWN TO BE COMBUSTIBLE AT ELEVATED
PRESSURES. THESE MIXTURES ARE POTENTIALLY
DANGEROUS AND MAY RESULT IN FIRE OR
EXPLOSION CAUSING INJURY OR PROPERTY
DAMAGE.
ANTIFREEZE IS AN ETHYLENE GLYCOL BASE
COOLANT AND IS HARMFUL IF SWALLOWED OR
INHALED. SEEK MEDICAL ATTENTION IMMEDI-
ATELY IF SWALLOWED OR INHALED. DO NOT
STORE IN OPEN OR UNMARKED CONTAINERS.
WASH SKIN AND CLOTHING THOROUGHLY AFTER
COMING IN CONTACT WITH ETHYLENE GLYCOL.
KEEP OUT OF REACH OF CHILDREN AND PETS.
DO NOT OPEN A COOLING SYSTEM WHEN THE
ENGINE IS AT RUNNING TEMPERATURE. PER-
SONAL INJURY CAN RESULT.
CAUTION: The engine cooling system is designed
to develop internal pressure of 97 to 123 kPa (14 to
18 psi). Allow the vehicle to cool a minimum of 15
minutes before opening the cooling system. Refer
to Group 7, Cooling System.
AND
ALTITUDE
IS

A/C APPLICATION TABLE

Item
Description
VEHICLE
JA Cirrus,
Stratus, Breeze,
JX Sebring
Convertible
SYSTEM
R134a
w/expansion
valve
COMPRESSOR
Sanden
TRS-090 (Scroll)
Freeze–up
evaporator temp
Control
probe (2-wire)
Low psi Control
pressure
transducer to
PCM
High psi Control
Thermal Limiter
cut Out >
Switch
252-262° F, cut
In < 225-235° F
CONTROL
manual type
HEAD
Mode Door
electric actuator
w/feedback
Blend Air Door
cable
Fresh/Recirc
cable
door
Blower Motor
hardwired to
control head
COOLING
PCM controlled
FANS
module, two fan
motors -
low/high
CLUTCH
Control
relay
Draw
2-4.15 amps @
12V
Gap
0.013 -0.025
DRB III
Reads
Mode door, TPS,
RPM, A/C switch
test
Actuators
clutch and fan
relays
JA
Notes
4-door sedan,
2-door
convertible
SP-15 PAG Oil
BCM input,
signals OFF <
33.7° F, ON >
35.7° F
opens < 29.4
psi
opens > 431
psi
scroll
compressors
only serviced
with clutch
resistive
multiplex signal
for A/C request
to BCM
BCM controlled
resistor block
low & high
relays
PCM
0.5V