Available languages

Available languages

Winter Storage
NOTICE
You must protect your unit from freezing
temperatures.
, Failure to do so will permanently damage your pump and render
your unit inoperable.
* Freezedamage is not covered under warranty.
Te protectthe unit from freezing temperatures:
1. Follow steps 1-4 in the previous section After Each Use.
2. Use pump saver, Model 6039, to treat pump. This
minimizes freeze damage and lubricates pistons and
seals.
3. If pump saver is not available, connect a 3 ft. (92 cm)
section of garden hose to water inlet adapter. Pour
RV-antifreeze(antifreezewithout alcohol) into hose.
PuiI recoil handle twice. Disconnect 3 ft. (92 cm) hose.
4. Store unit in a clean, dry area.
Long Term Storage
if you do not plan to use the pressure washer for more than
30 days, you must preparethe engine and pump for long
term storage.
Protect Fuel System
Fuel Additive:
Fuel can become stale when stored over 30 days. Stab fuel
causes acid and gum deposits to form in the fuel system or
on essential carburetor parts. To keep fuel fresh, use Briggs
& Stratten@ Advanced Formula Fuel Treatment &
Stabilizer, availablewherever Briggs & Stratton genuine
service parts are sold.
For engines equipped with a FRESHSTART@fuel cap, use
Briggs & Stratten FRESHSTART@available in a drip
concentrate cartridge.
There is no need to drain gasoline from the eng ne if a fuel
stabilizer is added according to instructions. Run the engine
for 2 minutes to circulate the stabilizer throughout the fuel
system before storage.
if gasoline in the engine has not been treated with a fuel
stabilizer, it must be drained into an approved container. Run
the engine until it stops from lack of fuel. The use of a fuel
stabilizer in the storage container is recommended to
maintain freshness.
Storing the Engine
See the engine operator's manual for instructions on how to
properly prepare the engine for storage.
Protecting the Pump
To protect the pump from damage caused by mineral
deposits or freezing, use PumpSaver,Model 6039, to treat
pump. This prevents freeze damage and lubricates pistons
and seals.
NOTICE PumpSaver is availableas an optional accessory, it
is not included with the pressure washer. Contact the nearest
authorized service center to purchase PumpSaver.
NOTICE You must protect your unit from freezing
temperatures.
, Failure to do so will permanently damage your pumpandrender
your unit inoperable.
* Freeze damageis not covered underwarranty.
To use PumpSaver, make sure the pressure washer is turned
off and disconnected from supply water. Read and follow all
instructions and warnings given on the PumpSaver
container.
Other Storage Tips
1. DO NOT store fuel from one season to another unless it
has been treated as described in Protect Fuel System.
2. Replacefuel container if it starts to rust. Rust and/or
dirt in fuel can cause problems if it's used with this
unit.
3. Cover unit with a suitable protective cover that does not
retain moisture.
A WARNING Storage covers could cause a fire
resulting in death, serious injury and/or property
damage.
* DO NOTplace a storage cover over a hot pressure washer,
Let equipment cool for a sufficient time before placing the cover
4. Store unit in a clean and dry area,