Winter Storage; Long Term Storage - Briggs & Stratton 020498 Operator's Manual

Table of Contents

Advertisement

Available languages

Available languages

Winter Storage

NOTICE You must protect your unit from freezing
temperatures.
• Failure to do so will permanently damage your pump and
render your unit inoperable.
• Freeze damage is not covered under warranty.
To protect the unit from freezing temperatures:
1. Follow steps 1-4 in the previous section After
Each Use.
2. Use pump saver, Model 6039, to treat pump. This
minimizes freeze damage and lubricates pistons
and seals.
3. If pump saver is not available, connect a 3 ft.
(92 cm) section of garden hose to water inlet
adapter. Pour RV-antifreeze (antifreeze without
alcohol) into hose. Pull recoil handle twice.
Disconnect 3 ft. (92 cm) hose.
4. Store unit in a clean, dry area.

Long Term Storage

If you do not plan to use the pressure washer for more
than 30 days, you must prepare the engine and pump
for long term storage.
Protect Fuel System
Fuel Additive:
Fuel can become stale when stored over 30 days.
Stale fuel causes acid and gum deposits to form in
the fuel system or on essential carburetor parts. To
keep fuel fresh, use Briggs & Stratton® Advanced
Formula Fuel Treatment & Stabilizer, available
wherever Briggs & Stratton genuine service parts are
sold.
There is no need to drain gasoline from the engine
if a fuel stabilizer is added according to instructions.
Run the engine for 2 minutes to circulate the stabilizer
throughout the fuel system before storage.
If gasoline in the engine has not been treated with a
fuel stabilizer, it must be drained into an approved
container. Run the engine until it stops from lack
of fuel. The use of a fuel stabilizer in the storage
container is recommended to maintain freshness.
Change Oil
While engine is still warm, drain oil from crankcase.
Refill with recommended grade. See Changing Engine
Oil in Engine Maintenance.
Protecting the Pump
To protect the pump from damage caused by mineral
deposits or freezing, use PumpSaver, Model 6039,
to treat pump. This prevents freeze damage and
lubricates pistons and seals.
NOTICE You must protect your unit from freezing
temperatures.
• Failure to do so will permanently damage your pump and
render your unit inoperable.
• Freeze damage is not covered under warranty.
NOTICE PumpSaver is available as an optional
accessory. It is not included with the pressure washer.
Contact the nearest authorized service center to
purchase PumpSaver.
To use PumpSaver, make sure the pressure washer is
turned off and disconnected from supply water. Read
and follow all instructions and warnings given on the
PumpSaver container.
Other Storage Tips
1. DO NOT store fuel from one season to another
unless it has been treated as described in Protect
Fuel System.
2. Replace fuel container if it starts to rust. Rust and/
or dirt in fuel can cause problems if it's used with
this unit.
3. Cover unit with a suitable protective cover that
does not retain moisture.
WARNING Storage covers could cause a fire
resulting in death or serious injury.
• DO NOT place a storage cover over a hot pressure
washer.
• Let equipment cool for a sufficient time before placing the
cover on the equipment.
4. Store unit in a clean and dry area.
21