Service Bulletin 4812 712 40313 - Whirlpool AWO/D 43115 Service Information

Frontloader
Hide thumbs Also See for AWO/D 43115:
Table of Contents

Advertisement

SERVICE

Service Bulletin 4812 712 40313

AUTHOR: Juergen Reinhardt
Last Update: 11/17/09
VERSION: 1.0
TITLE: F06 randomly displayed in Domino controls
CAUSE
Sensible failure detection in drive system for safety reasons
REMEDIAL ACTION
Please check the following points:
Load:
Was there bulky load in the drum or was the machine overloaded ?
Drive system:
Please check the tacho generator (resistance and cable).
Please guarantee a proper and tight seat of the belt on drive shaft and pulley.
Please check the electrical connections between controls and motor.