Download Print this page

Daikin RKD50BVM Service Manual page 16

5.0/6.0/7.1/8.0 kw class 18000/24000/28000 btu/h class
Hide thumbs Also See for RKD50BVM:

Advertisement

Removal of PCBs / Electrical Box
Step
8
Disconnect the
connectors and remove
the main PCB.
Disconnect the relay
9
connector for the
compressor.
14
Procedure
[S91]
[S31]
[S71]
[S33]
[S10]
[S80]
[S51]
[S101] [S20] [S90] [S40] [S91]
[S32] [H2]
[H1]
(blue)
(yellow)
(R2712)
[Fu2]
(R19136)
(R17065)
Si00-876
Points
[S10]: terminal board
[S20]: electronic expansion
valve
[S31]: CN14 on SPM
[S32]: CN11 on SPM
[S33]: [S34] on MID
[S40]: overload protector
[S51]: [S52] on service monitor
PCB
[S71]: [S72] on MID
[S80]: four way valve
[S90]: thermistors
[S91]: radiation fin thermistor
[S101]: [S102] on service
monitor PCB
[H1] [H2]: diode bridge
[S32]
[S33]
[S71]
[S31]
Removal Procedure

Hide quick links:

Advertisement

loading