Suburban NAUTILUS IW60 Installation And Operation Manual

Suburban NAUTILUS IW60 Installation And Operation Manual

On demand water heater direct vent gas with direct spark ignition

Advertisement

INSTALLATION AND OPERATION MANUAL
WARNING
Failure to follow safety warning exactly
could result in serious injury, death or
property damage.
— Do not store or use gasoline or
other
flammable
liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
Evacuate all persons from the
vehicle.
Shut off the gas supply at the gas
container or source.
Do not touch any electrical switch,
or use any phone or radio in the
vehicle.
Do not start the vehicle's engine
or electric generator.
Contact the nearest gas supplier
or qualified service technician for
repairs.
If
you
cannot
supplier
or
technician, contact the nearest
fire department.
Do not turn on the gas supply until
the gas leak(s) has been repaired.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
Part Number 205256
10-31-2017
NAUTILUS ON DEMAND WATER HEATER
(IW60) DIRECT VENT GAS
with DIRECT SPARK IGNITION
FOR INSTALLATION IN RECREATIONAL VEHICLES
vapors
and
reach
a
gas
qualified
service
FREEZE WARNING
Drain or fill with RV approved antifreeze
if subject to freezing temperatures when
storing for winter.
WARNING
Installation of this appliance must be made
in accordance with the written instructions
provided
in
this
representative or employee of Suburban or
other person has the authority to change,
modify or waive any provision of the
instructions contained in this manual.
Improper adjustment, alteration, service,
Maintenance or installation can cause
serious injury or death.
Read and follow all instructions and
precautions in this manual. Installation and
service must be performed by a qualified
service agency or the gas supplier.
AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER
HEATER.
INSTALLER: AFFIX THESE INSTRUCTIONS TO OR ADJACENT
TO WATER HEATER.
OWNER: RETAIN THESE INSTRUCTIONS AND WARRANTY FOR
FUTURE REFERENCE.
ALL TECHNICAL AND WARRANTY QUESTIONS SHOULD BE
DIRECTED TO THE COMPANY LISTED ON THE WARRANTY OR
RATING PLATE WHICH CAME WITH YOUR WATER HEATER.
AIRXCEL, INC. - SUBURBAN DIVISION
676 Broadway Street • Dayton, Tennessee 37321
manual.
No
agent,
423-775-2131 • www.Airxcel.com

Advertisement

Table of Contents
loading

Summary of Contents for Suburban NAUTILUS IW60

  • Page 1 Suburban or — WHAT TO DO IF YOU SMELL GAS other person has the authority to change, • Evacuate all persons from the modify or waive any provision of the vehicle.
  • Page 2 For your safety, do not terminate A Suburban vent cap must be installed on the unit and all the vent on your water heater inside add-on side inspection panels must be in place for proper water rooms, screen porch or onto patios.
  • Page 3 Do not short out terminals INSTALLATION USING REPLACEMENT PANEL A replacement panel is used when replacing Suburban 6, 10, 12, and 16 gallon tank on gas valve or primary control to test. Short or incorrect units and Atwood Style 6 and 10 gallon tank units.
  • Page 4 IMPORTANT: Use a pipe thread compound suitable for potable water or pipe thread • If you cannot reach a gas supplier or qualified service technician, contact the tape on all connections to assure they will not leak. nearest fire department. B.
  • Page 5 E. Check manual reset on ECO switch. Refer to DETAIL "A" in Figure 9. B. Unit thermostat is set at 120°F at the factory. Cold water must be added to If burner fails to light, call a Suburban service center or a local RV service agency. achieve the desired hot water temperature.
  • Page 6 Do not plug the relief valve under any circumstances. technician. Suburban recommends that a check valve not be installed directly at the inlet to the water heating unit. PARTS AND SERVICE WARNING Contact a conveniently located recommended Suburban Service Center.
  • Page 7 SCREW UNIT TO FLOOR AS SHOWN ELECTRICAL CONNECTION WATER SUPPLY INLET FREEZE PROTECTION NEEDLE VALVE SYSTEM DRAIN LINE 5/8" I.D. TUBING WATER SUPPLY OUTLET CONDENSATE DRAIN 1/2" I.D. TUBING CONNECTION Figure 5 (BACK VIEW) RV WALL APPLY SILICONE COMPLETELY AROUND BACK SIDE OF VENT FLANGE (MUST BE SEALED TO OUTER WALL) Figure 6...
  • Page 8 ALTERNATE MOUNTING BRACKET LOCATION REAR OF UNIT ACCESS PANEL "Y" MOUNTING SCREWS ACCESS PANEL WITH FRAME GASKET SUBURBAN ACCESS PANEL "Y" DIMENSION 6 GALLON 4.895" 10 GALLON 6.634" Figure 7B SILICONE OR CAULKING AROUNG OPENING FOR 10 GALLON ACCESS PANEL...
  • Page 9 LEFT SIDE ACCESS PANEL SERVICE PANEL MANUAL ECO SWITCH DETAIL A Figure 9 SYSTEM DRAIN CONTROL KNOB GREEN GROUND SCREW FREEZE PROTECTION SYSTEM DRAIN NEEDLE VALVE 5/8" I.D. TUBING CONDENSATE DRAIN 1/2" I.D. TUBING Figure 10...
  • Page 10 SPARK LIGHT IS ONLY TO BE ELECTRODE USED WITH BLUE AND ON DEMAND ORANGE WIRES FROM CONTROL IW60. TO AVOID DAMAGE FLAME PROBE W1 W2 CENTER TO THE MODULE BOARD, DO NOT CONNECT SUPPLY VOLTAGE TO LAMP. AIR PRESSURE SWITCH LAMP BK -12 V.D.C.
  • Page 11 OPTIONAL ON DEMAND CONTROL CENTER DISPLAY DESCRIPTION 2 BURNERS BURNERS 5 BURNERS This icon is displayed when FLAME FLAME is established. This icon is displayed when the BLOWER BLOWER is running This icon is displayed when the STATUS Water Heater is in standby mode, INDICATOR ready to be used.
  • Page 12 THE SERVICE AGENCY FOR WARRANTY REPAIRS; SUCH PAYMENTS WILL NOT BE REIMBURSED. Suburban reserves the right to examine the alleged defect in the water heater or component parts, and it is the owner’s obligation to return the water heater and/or component parts to Suburban or its representative. When returning a water heater, it must include all component parts and the serial number plate.

Table of Contents