Toshiba RAV-GM 801UT-E Service Manual page 114

Split type, outdoor unit
Table of Contents

Advertisement

No. Part name
Electric
3. Detachment (Reactor)
part
1) Following to work of Detachment of
(Reactor)
2) Remove the connector of the reactor lead wire
connected to the reactor. (2 positions)
3) Remove the connector.
( Ø4 ST3T, 2 pcs,)
4. Attachment (Reactor)
Attach the reactor in the reverse process of the
"3. Detachment (Reactor)".
1.Detachment
Fan motor
1) Following to work of Detachment of
2) Make sure that the fan motor and the propeller fan
stop.
Remove the flange nut from the fan motor and
propeller fan.
• Loosen the flange nut by turning clock wise.
3) Remove the propeller fan.
4) Following to work of Detachment of
5) Cut the binding band A4 ( Thickness :1.1 mm, Width
:2.5 mm) bundling the case thermostat lead and the
reactor lead × 2
6) Remove the connector for the fan motor lead.
Remove the clamp filter from the fan motor lead.
(It is used after replacement.)
7) Remove the fan motor lead from the fixing rubber for
separate plate.
Procedure
(To tighten the flange nut, turn it counter clockwise)
[Detail.C]
,
and
.
, 1) to 5).
Pass the binding band A4
through the hole on the
clamp filter, and then
bundle two reactor leads.
– 114 –
Remarks
Reactor
Reactor lead × 2
Propeller fan
Propeller fan
Propeller fan
Fan motor
Fan motor
Fan motor
Flange nut
(Loose it tuning to right)
Compressor case thermostat lead
(Black tube)
[Detail. C]
[Detail. C]
[Detail. C]
4-way valve coil lead
4-way valve coil lead
4-way valve coil lead
(1 : Yellow , 1 : Red )
(1 : Yellow , 1 : Red )
(1 : Yellow , 1 : Red )
Binding band A4
Binding band
Binding band
Binding band A1
Fan motor lead fixing rubber
Protrusion/refrigeration
cycle side
Reactor lead
Reactor lead
Reactor lead
(White × 2)
(White × 2)
(White × 2)
Clamp filter
Clamp filter
Clamp filter
Separate plate