2 Product Overview

2
Product Overview
u
About This Product
The PG-B3 Option allows the user to connect an incremental encoder with complementary
output (PG) for motor speed feedback to the drive to increase the control accuracy and
performance in V/f w/PG, CLV, and AOLV control methods.
This PG encoder signal allows the drive to compensate for subtle variations in the load while
providing the drive with the necessary data to control the output frequency and maintain an
accurate constant speed.
The option reads a 50 kHz maximum input frequency from the PG encoder. Select a PG
encoder with 50 kHz maximum output when operating at maximum speed.
u
Applicable Models
The option can be used with the drive models in
Drive Series
8
Table 1 Applicable Models
A1000
L1000A
U1000
U1000L
GA700
CR700
CH700
YASKAWA ELECTRIC TOBP C730600 75B YASKAWA AC Drive Option PG-B3 Installation Manual
Table
1.
Model Number
All models
All models
All models
All models
All models
All models
All models