Specifications; Cautions For Proper Use - Panasonic MINAS-BL KV Series Technical Instructions

Brushless amplifier
Hide thumbs Also See for MINAS-BL KV Series:
Table of Contents

Advertisement

Specifications

Item
Brushless
MBEK
MBEK
amplifier
5A1BCV
5A5BCV
Model
name
Brushless
MBMS5AZBL
motor
Rated output (W)
50
Single
Single/
Voltage (V)
phase
3-phase
Tolerance ±10 %
100 to 120
200 to 240
Power
input
Frequency (Hz)
Rated input
1.8
0.9/0.5
current (A)
Motor Rated Current (A)
0.74
Rated torque (N・m)
0.16
Starting torque (N・m)
0.3
Rated rotation speed
Speed control range
With load
±0.5 % or below (at 0 to rated torque, rated rotation speed)
Speed
With voltage
±0.5 % or below (at supply voltage ±10 %, rated rotation speed)
fluctuation
factor
With
temperature
Acceleration/
Deceleration time
Stopping procedure
(A slowdown stop and a free-run stop to selection is possible)
100 to 4000 r/min (analogue voltage (0 to 5 V), console A),
Speed control range
100 to 4000 r/min (Setting selection by parameter on Digital key pad)
Speed setting Resolution
Analogue: About 1/ 200 of Upper speed limit Digital: 1 r/min
Analogue: ±3 % or below of upper limit speed
Speed setting precision
(±90 r/min or below at upper limit speed 3000 r/min)
(at 20 °C)
Regenerating brake
Regenerative braking resistor can be externally connected.
Overload, Overcrrent, Overvoltage, Parameter error,
CPU error, Overspeed, Sensor error, Overheat, setting change.External
Protective function
User parameter error, System parameter error
Overload protection
Amplifier mass (kg)
0.37
*1 Can be set by using the optional Digital key pad DV0P3510 (sold separately) or PANATERM
for BL or through communication over RS485.
Specifications
MBEK
MBEK
MBEK
MBEK
MBEK
011BCV
015BCV
021BCV
025BCV
045BCV
MBMS
MBMS
MBMS
MBMS
MBMS
011BL
012BL
021BL
022BL
042BL
100
200
Single
Single/
Single
Single/
Single/
phase
3-phase
phase
3-phase
3-phase
100 to 120
200 to 240
100 to 120
200 to 240
200 to 240
50/60
2.4
1.3/0.7
4.2
2.1/1.2
3.8/2.1
1.4
0.76
2.9
1.8
0.32
0.64
1.27
0.7
1.4
3000 r/min
100 r/min to 4000 r/min (Speed ratio 1:40)
±0.5 % or below
0.3 sec
*1
Free-run stop
[Digital: 1 % or below of upper limit speed]
forced trip, RS485 communication error,
Inverse time-lag overload protection
Protection level 115 (Torque command)
1.0
- 14 -

Cautions for Proper Use

Cautions for Proper Use
• Practical considerations for exporting the product or assembly containing the product
MBEK
083BCV
When the end user of the product or end use of the product is associated with military
affair or weapon, its export may be controlled by the Foreign Exchange and Foreign Trade
MBMS
082BL
Control Law. Complete review of the product to be exported and export formalities should
be practiced.
400
750
• Parts are subject to minor change to improve performance.
3-phase
• This product is intended to be used with a general industrial product, but not designed or
200 to 240
manufactured to be used in a machine or system that may cause personal death when it
is failed.
• Install a safety equipments or apparatus in your application, when a serious accident or
4.0
loss of property is expected due to the failure of this product.
• If you are planning to use this product under special environment, such as atomic power
2.8
3.6
control, aerospace equipment, traffic organization, medical equipment, various safety
2.4
systems, and equipment which requires cleanliness, please contact us.
3
5.2
• We have been making the best effort to ensure the highest quality of the products,
however, application of exceptionally larger external noise disturbance and static
electricity, or failure in input power, wiring and components may result in unexpected
action. It is highly recommended that you make a fail-safe design and secure the safety in
the operative range.
• When this product is operated without the shaft electrically grounded, such as in driving
the fan, bearing noise may become higher due to the occurence of electrocorrosion
depending on the motor used or setting emvironment, so confirm and verify the condition
on the customer side in such a case.
• Failure of this product depending on its content, may generate smoke of about one
*1
cigarette. Take this into consideration when the application of the machine is clean room
related.
• Please be careful when using in an environment with high concentrations of sulphur or
sulphuric gases, as sulphuration can lead to disconnection from the chip resistor or a poor
contact connection.
• Take care to avoid inputting a supply voltage which significantly exceeds the rated range
to the power supply of this product. Failure to heed this caution may result in damage to
the internal parts, causing smoking and/or a fire and other trouble.
- 15 -

Advertisement

Table of Contents
loading

Table of Contents