Specifications - Panasonic FX-501 Series Instruction Manual

Digital fiber sensor amplifier
Table of Contents

Advertisement

Specifications

17
Type
Model number
NPN output
PNP output
Supply voltage
Power consumption
Output (FX-502□ and FX-505□-C2 only:
output 1, output 2)
Number of outputs
Output operation
Short‑circuit protection
Response time
Analog output (FX-505□-C2 only)
External input (switchable with output 2 for
FX-502□)
Protection
Ambient temperature
Ambient humidity
Material
Cable
Weight (main body only)
Accessory
1. Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23°C.
notes:
: 50mA max. if 5 or more series connection types are connected together (25mA for FX-502
2. FX-501
3. Only if you are using the quick‑connection cable (optional, cable length 5m).
4. If the digital display has been adjusted manually, the figures displayed may be outside the range.
Cable
Amplifier
Main cable
CN‑73‑C1
FX-501
FX-502
CN‑74‑C1
*
You can extend the cable up to 100m max. with 0.3mm
standard type
FX-501
FX-501P
Normal operation: 960mW or less (current consumption 40mA or less at 24V supply voltage)
Eco mode: 680mW or less (current consumption 28mA or less at 24V supply voltage)
nPn open-collector transistor
● Maximum sink current (see note 2):
FX-501: 100mA
FX-502, FX-505: 50mA
● Applied voltage: 30V DC or less between sensing output and 0V
● Residual voltage: 2V or less (see note 3) at maximum sink current
PnP open-collector transistor
● Maximum source current (see note 2):
FX-501P: 100mA
FX-502P, FX-505P: 50mA
● Applied voltage: 30V DC or less between sensing output and +V
● Residual voltage: 2V or less (see note 3) at maximum source current
1
H-SP: 25μs or less, FAST: 60μs or less, STD: 250μs or less, LONG: 2ms or less, U-LG: 4ms or less, HYPR: 24ms or less
‑10 to +55°C (no dew condensation or icing allowed)
● For 4 to 7 units mounted in cascade: ‑10 to +50°C
● For 8 to 12 units mounted in cascade: ‑10 to +45°C)
Storage: ‑20 to +70°C
Cables are not supplied with the product. Select cables from the table below,
Cable length 1m
Sub cable
CN‑71‑C1
CN‑72‑C1
2
or more cable. However, in order to reduce noise, make the wiring as short as possible.
2-output type
FX-502
FX-502P
12 to 24V DC % (+10% / ‑10%), ripple P‑P10% or less
Switchable either Light‑ON or Dark‑ON
Incorporated
signal condition of nPn non-contact input:
● High: +8V to +V DC or Open
● Low: 0 to +1.2V DC (at 0.5mA source current)
● Input impedance: Approx. 10kΩ
signal condition of PnP non-contact input:
● High: +4V to +V DC (at 3mA sink current)
● Low: 0 to +0.6V DC or Open
● Input impedance: Approx. 10kΩ
IP40 (IEC)
35 to 85% RH, Storage: 35 to 85% RH
Enclosure: polycarbonate, switch: TPEE, protective cover: polycarbonate
Approx. 15g
FX-MB1 (Amplifier protection seal): 1 set.
Cable length 2m
Main cable
Sub cable
CN‑73‑C2
CN‑71‑C2
CN‑74‑C2
CN‑72‑C2
http://panasonic-electric-works.net/sunx
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
Europe Headquarter: Panasonic Electric Works Europe AG
Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany
Phone: +49-8024-648-0
US Headquarter: Panasonic Electric Works Corporation of America
629 Central Avenue, New Providence, New Jersey 07974, USA
Phone: +1-908-464-3550
8
2
● Output current: approx. 4 to 20mA
(display in H‑SP, FAST, STD: 0
to 4,000, display in LONG: 0 to
8,000 (see note 4))
● Response time: 2ms or less
● Zero point: within 4mA ±1%F.S.
● Span: within 16mA ±5%F.S.
● Linearity: within ±3%F.S.
● Load resistance: 0 to 250Ω
2
0.2 mm
)
Cable length 5m
Main cable
CN‑73‑C5
CN‑74‑C5
Cable type
FX-505-C2
FX-505P-C2
6‑core cab tire cable, 2m
Approx. 60g
Sub cable
CN‑71‑C5
CN‑72‑C5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx-502 seriesFx-505-c2 series

Table of Contents