Spare Parts; Applicable Standards - Siemens 1SE0 Operating And Maintenance Manual

Three-phase induction motor 63-132 frame sizes
Table of Contents

Advertisement

Caution
(Environmental Protection)
The bearing to be discarded must be
thoroughly cleaned from grease and
should be intentionally damaged (using
weld marks or cutters etc) to avoid
reuse.
The removed grease is a hazardous
waste and is harmful to environment
causing soil pollution and water
pollution. It should only be incinerated
at an authorized agency and not
disposed by any other means.
It is recommended that the new rolling
contact bearings be installed as follows:
Heat the deep groove ball bearing in oil
or air to a temperature of approximately
80°C and slip them over the shaft. Heavy
blows may damage the bearing and must
be avoided.
When replacing the bearings, it is also
advisable to replace any sealing elements
that are subject to wear (e.g. oil seal, felt
etc.).
Caution
(Environmental Protection)
Waste insulation material is a hazardous
waste and it should only be incinerated
at an authorized agency and not
disposed by any other means.
Replace any other damaged parts. For
Spare parts contact the nearest SIEMENS
sales office.
5.5
Joint sealing
When reassembling machines with degree
of protection IP56 (see rating plate), the
joint between the motor frame and the
endshields are sealed with rubber 'O' rings.
It should be ensured that these are not
damaged.
6.

Spare Parts

When ordering spare parts, please indicate
the correct Motor Type, Serial Number (as
shown on the rating plate) and also the
correct part description. This will ensure
speedy and correct delivery of spare parts.
Please refer to the exploded view of the
motor (Fig.1).
Caution
(Environmental Protection)
Disposal of the product at the end
of its life: When it is decided that
the product cannot be repaired and
is to be disposed off, care should be
taken to adhere to Local / Statutory
environmental requirements. It should
be noted that the product contains
grease, copper windings, insulation
materials that are not biodegradable
and are hazardous to the environment.
NOTE:
In addition to the above information, it is
recommended that the user refer to IS: 900
– "Code of practice for installation and
maintenance of Induction Motors".

Applicable Standards

The motors comply with the following
standards:
IS: 12615: Specification for three phase
induction motors
IS: 900: Code of practice for installation
and maintenance of induction motors.
IS: 4691: Degree of protection provided by
enclosure for rotating electrical machinery
15