Denso QS20P-A User Manual page 34

2d code scanner ac adapter driven
Table of Contents

Advertisement

Transmission rate
4800, 9600, 19200, 38400, 57600, or 115200 bps
Transferable characters and port settings
If not specified as binary codes, all data will be treated as ASCII codes. Listed
below are port settings you can select. If data contains double-byte Japanese
Kanji or binary data when the character length is set to 7 bits, the QS20P-A will
ignore the MSB.
Start bit
Character length
Parity check
Stop bit
Transmission format
Header
Code ID mark
(1)
Header
You may select either "No header" or STX.
(2)
Terminator
You may select ETX, CR, LF, or CR LF.
(3)
BCC
Every parity bit of BCC (block check character) is set so that all set bits at the
same bit level (including a parity bit) in the characters contained in the transmis-
sion block have an even number by exclusing-ORing. Those characters do not
contain a header but include a terminator.
You may select whether BCC will be transferred. Note that BCC cannot be
transferred if the transmission block contains no header.
1 bit (fixed)
7 or 8 bits
Even, Odd, or None
1 or 2 bits
No. of digits
n1 n2 n3 n4
22
Data read
Terminator
BCC