5.2 Alarm Codes

ID
Description Text
01
AIS: Tx malfunction
AIS: Antenna VSWR
exceeds limit
02
(VSWR - Voltage
Standing Wave Ratio)
AIS: Rx channel 1
03
malfunction
AIS; Rx channel 2
04
malfunction
AIS: Rx channel 70
05
malfunction
06
AIS: General failure
AIS; External EPFS lost
(EPFS = electronic
25
Position Fixing System
such as GPS)
AIS: No sensor position
26
in use
AIS: No valid SOG
29
information
AIS: No valid COG
30
Information
32
AIS: Heading lost/invalid
AIS: No valid ROT
35
Information
User Manual
Cause/Source
Reaction: The transponder unit stops transmission. If Alarm ID 01 and
ID 02 are simultaneously displayed, then a major antenna problem has
arisen.
Remedy:
VHF Antenna,
Check if the antenna is AIS compatible (156-162 MHz) and if the
cabling
antenna cabling has a short circuit or is missing any contacts at the
connectors.
If the ID 01 is displayed as a stand alone message, then the unit
requires replacing.
Reaction: The transponder unit continues transmission.
VHF antenna,
Remedy:
Check the antenna and the antenna cabling (RG214 / 50 Ohm cable
installation
required).
Reaction: The transponder unit stops transmission on the affected
channel,
Internal error
Remedy;
If this alarm reoccurs regularly, then the transponder unit requires
replacing.
Reaction: The transponder unit stops transmission.
Internal error
Remedy;
The transponder unit requires replacing.
Reaction: The transponder unit continues operation using the position
data of the internal GPS. If there is no valid position data available from
the internal GPS, error 026 is additionally displayed.
No valid data on
Remedy:
Ch1, Ch2 or Ch3
Id 25 indicates that the sentences GLL, GNS, GGA, RMC cannot be
is available
received. Check the sensor and the cabling; check if the system that
delivers the data is working. Check the baud rate settings of the sensor
inputs. AIS requires the protocol NMEA 0183 V3.0!
No valid position
Reaction: The transponder unit continues operation.
from internal GPS
Remedy:
or external
Check the sensor cabling and the antenna of the internal GPS sensor.
position sensor
Reaction: The transponder unit continues operation and displays SOG:
N/A
No valid data from
Remedy:
external speed
The sentences VBW, VTG, RMC cannot be received. Check the sensor
sensor or internal
and the cabling; check if the system that delivers the data is working.
GPS
Check the baud rate settings of the sensor inputs. AIS requires the
protocol NMEA 0183 V3.0!
Reaction: The transponder unit continues operation and displays COG:
N/A
No valid data from
Remedy:
external sensor or
The sentences VBW, VTG, RMC cannot be received. Check the sensor
and the cabling, check if the system that delivers the data is working.
internal GPS
Check the baud rate settings of the sensor inputs. AIS requires the
protocol NMEA 0183 V3.0!
Reaction: The transponder unit continues operation
Remedy:
No valid data from
The sentence for HDT cannot be received. Check the sensor and the
external sensor
cabling, check if the system that delivers the data is working. Check the
(Gyrocompass)
baud rate settings of the sensor inputs. Mention AIS accepts true
heading only (no magnetic).
Reaction: The transponder unit continues operation
Remedy:
No ROT indicator
The sentence for ROT cannot be received. If a Rate Of Turn indicator is
is used.
not in use, then it suffices to just acknowledge the alarm. The Alarm
Status will store the information that no ROT sensor is available.
No valid data from
Otherwise, check the sensor and the cabling. Check if the system that
external sensor
delivers the data is working. Check the baud rate settings of the sensor
inputs. The AIS requires the protocol NMEA 0183 V3.0!