SCHEMATIC DIAGRAMS

Description:
VOLTAGE MEASUREMENT CONDITION:
1. The voltages at test points are measured on exclusive AC adaptor and the stable supply voltage of AC 230V.
Signals are fed by a color bar signal generator for servicing purpose and the above voltages are measured with a
20k ohm/V tester.
INDICATION OF RESISTOR & CAPACITOR:
RESISTOR
(K=kΩ=1000 Ω, M=MΩ).
1. The unit of resistance "Ω " is omitted.
2. All resistors are ± 5%, unless otherwise noted. (J= ± 5%, F= ± 1%, D= ± 0.5%)
3. All resistors are 1/16W, unless otherwise noted.
4. All resistors are Carbon type, unless otherwise noted.
: Solid
: Cement
C
W
: Oxide Film
: Special
S
T
: Metal Coating
N
CAPACITOR
1. All capacitors are µF, unless otherwise noted. (P=pF=µµ F).
2. All capacitors are 50V, unless otherwise noted.
3. All capacitors are Ceramic type, unless otherwise noted.
(ML): Mylar
(TA): Tantalum
(PF): Polypro Film
(ST): Styrol
CAUTION:
This circuit diagram is original one, therefore there may be a
slight difference from yours.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH "
" (
!
IMPORTANT FOR MAINTAINING THE SAFETY
OF THE SET. BE SURE TO REPLACE THESE
PARTS
WITH
SPECIFIED
MAINTAINING
THE
SAFETY
PERFORMANCE OF THE SET.