1L1
Contactor
TECO
7.
Turn the dial on the overload relay to 19.5A
for 110V (see Figure 16).
CU-18
240V
2T1
21.5 A
TRIP IND.
20
19
19.5A
18
Relay
TEST
RCA
Setting
97NO
98NO
97 NO
98 NO
2T1
Figure 16. Model G0807 overload relay set to
19.5A.
8.
Remove six screws securing the grinding and
welding control panel to access grinding unit
wiring.
-18-
5L3
3L2
13NO
21NC
13NO
21NC
22NC
14NO
14NO
4T2
6T3
A2
O
R
TECO Relay
17.5
RHU-17.5-21.5
95NC
96NO
95 NC
96 NC
4T2
6T3
9.
Remove the wire connected to the #4 termi-
nal on the welding transformer, and move it to
the #2 terminal; remove the wire connected
to the #5 terminal, and move it to the #3 ter-
minal (see Figure 17). The machine is now
wired for 110V.
Wires Reconnected
Terminals #2 & #3
1
2
3
T
Figure 17. Welding transformer rewired for
110V.
10. Close and secure the electrical cabinet, re-
install control panel, and secure the motor
junction box.
11. Install an L5-30 plug according to manufac-
turer's instructions.
Model G0806/G0807 (Mfd. Since 12/15)