Grizzly G0806 Owner's Manual page 18

Variable-speed vertical metal-cutting bandsaw
Table of Contents

Advertisement

Contactor
TECO
7.
Turn the dial on the new overload relay to
7.2A for 220V (see Figure 11).
CU-18
240V
2T1
4T2
10A
TRIP IND.
9
8
TECO Relay
7.2
TEST
RCA
RHU-10/1 7.2-10A
97NO
98NO
95NC
7.2A
97 NO
98 NO
4T2
2T1
Relay
Setting
Figure 11. Model G0806 overload relay set to
7.2A.
8.
Remove the six screws securing the grinding
and welding control panel to access grinding
unit wiring.
-16-
13NO
21NC
13NO
21NC
22NC
14NO
14NO
6T3
A2
O
R
96NO
95 NC
96 NC
6T3
9.
Remove the wire connected to the #4 termi-
nal on the welding transformer and move it to
the #7 terminal; remove the wire connected
to the #2 terminal and move it to the #5 ter-
minal (see Figure 12). The machine is now
wired for 220V.
Wires Reconnected
Terminals #5 & #7
1
2
3
4
T
Figure 12. Welding transformer rewired for
220V.
10. Close and secure the electrical cabinet, re-
install control panel, and secure the motor
junction box.
11. Install a 6-15 plug according to manufac-
turer's instructions.
Model G0806/G0807 (Mfd. Since 12/15)
5
6
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

G0807

Table of Contents