EdgeStar BIDW1802 Service Manual page 26

18” built-in dishwasher
Table of Contents

Advertisement

6. Remove clamps and pump outlet hose.
7. Remove clamps and pump inlet hose.
8. Disconnect the motor wire harness, the motor ground wire and rubber bracket.
Note: Factory-installed hose clamps are not reusable. Replace the old clamps with
new screw type hose clamps.
To remove the motor capacitor:
1. Follow steps 1 through 3 above.
2. The capacitor is connected to the motor with 2 wires and held in place with a nut.
Disconnect the wires and the nut.