6. Remove clamps and pump outlet hose.
7. Remove clamps and pump inlet hose.
8. Disconnect the motor wire harness, the motor ground wire and rubber bracket.
Note: Factory-installed hose clamps are not reusable. Replace the old clamps with
new screw type hose clamps.
To remove the motor capacitor:
1. Follow steps 1 through 3 above.
2. The capacitor is connected to the motor with 2 wires and held in place with a nut.
Disconnect the wires and the nut.