Inspection and maintenance work
The table below lists the manufacturer requirements with respect to minimum inspection and maintenance intervals. If na-
tional regulations and directives require shorter inspection and maintenance intervals, you should observe these instead of
the intervals listed. Each time inspection and maintenance work is carried out, carry out the required preparatory and com-
pletion work.
#
Maintenance work
1
Check the tightness of the air/flue pipe, make sure that it is not damaged
and has been attached correctly, and check that it has been set up cor-
rectly
2
Removing dirt from the product and the vacuum chamber
3
Visually check the heat cell to ascertain its condition and detect any cor-
rosion, rust or damage, and carry out maintenance work, if required
4
Checking the gas connection pressure at maximum heat input
5
Checking the CO₂ content and, if necessary, adjusting it (air index setting)
6
Recording the CO
7
Check that the connections/electrical plug connections have been con-
nected correctly/function correctly (product must be voltage-free)
8
Check that the gas stopcock and service valves function correctly
9
Checking the condensate trap for dirt and cleaning it
10
Checking the pre-charge pressure of the expansion vessel
11
Checking the insulating mats in the combustion area and replacing dam-
aged insulating mats
12
Cleaning the heat exchanger
13
Check the burner for damage
14
If the water volume is insufficient (domestic hot water) or the outlet tem-
perature is insufficient, check the secondary heat exchanger
15
Cleaning the filter in the cold water inlet
16
Check the impeller sensor for dirt/damage
17
Filling the heating installation
18
Run the test operation on the product/heating installation including
domestic hot water generation (if available) and, if required, purge the
product/heating installation
19
Visually check the ignition and burner behaviour
20
Re-checking the CO₂ content (the air ratio)
21
Check the product for gas, flue gas and water leaks
22
Completing inspection and maintenance work
40
content (the air ratio)
2
Interval
Annually
Annually
Annually
Annually
Annually
Annually
Annually
Annually
Annually
If required, at least every
2 years
If required, at least every
2 years
If required, at least every
2 years
If required, at least every
2 years
If required, at least every
2 years
If required, at least every
2 years
If required, at least every
2 years
If required, at least every
2 years
Annually
Annually
If required, at least every
2 years
Annually
Annually
Installation and maintenance instructions ecoTEC pro 0020244995_02
22
28
29
19