  • Page 1 0313-7201-00_(PWFPH_B_L)_PEUK_V10.qxp:_ 2015.12.3 2:55 PM Page 1 MODELS 10-year Op cal Smoke Alarm User Guide 0843-CPR-0265 WFPV 0843-CPR-0266 0843-CPR-0267 WFPL Sealed-in Ba ery lasts the life of the alarm EN14604:2005 WFPL WFPV Voice Unit / Living Area Unit Hallways Unit with Escape Light...
  • Page 2: Table Of Contents

    0313-7201-00_(PWFPH_B_L)_PEUK_V10.qxp:_ 2015.12.3 2:55 PM Page 1 Contents 1. Smoke Alarm Best Prac se 2. Important Smoke Alarm Informa on 3. Where to install a Smoke Alarm 4. Where not to install a smoke alarm 5. Installa on of your alarm 6.
  • Page 3: Smoke Alarm Best Prac Se

    0313-7201-00_(PWFPH_B_L)_PEUK_V10.qxp:_ 2015.12.3 2:55 PM Page 2 1. SMOKE ALARM BEST PRACTISE At all mes and before installing your smoke alarm you must; • Have an escape plan with alternate exits • Train your family in this escape plan and prac se it regularly •...
  • Page 4: Important Smoke Alarm Informa On

    0313-7201-00_(PWFPH_B_L)_PEUK_V10.qxp:_ 2015.12.3 2:55 PM Page 3 2. IMPORTANT SMOKE ALARM INFORMATION • Before temporarily silencing the alarm with the Hush bu on, iden fy the source of the smoke. • Smoke alarms need to be tested regularly • Smoke alarms cannot provide an alarm if smoke cannot reach them •...
  • Page 5: Where To Install A Smoke Alarm

    0313-7201-00_(PWFPH_B_L)_PEUK_V10.qxp:_ 2015.12.3 2:55 PM Page 4 3. WHERE TO INSTALL A SMOKE ALARM Locate one alarm on every floor level Locate to monitor stairways – Escape Light alarm recommended (Model WFPL) Locate in each sleeping loca on / bedroom – Voice alarm recommended (Model WFPV) Locate in every room with electrical appliances Hallways longer than 9m require a smoke alarm at each end –...
  • Page 6: Where Not To Install A Smoke Alarm

    0313-7201-00_(PWFPH_B_L)_PEUK_V10.qxp:_ 2015.12.3 2:55 PM Page 5 4. WHERE NOT TO INSTALL A SMOKE ALARM Garages • Areas of extreme temperature (below 0 °C and above 40 °C) • Dusty or insect infested areas • Do not install where the ven la on openings in the unit could be impeded by items •...
  • Page 7: Installa On Of Your Alarm

    0313-7201-00_(PWFPH_B_L)_PEUK_V10.qxp:_ 2015.12.3 2:55 PM Page 6 5. INSTALLATION OF YOUR ALARM OPTION 1 - Easy mount to drywall only; Ribs (2 1. Choose a mounting location (wall or ceiling) and drill a 5mm places) hole through drywall. 2. Insert the provided screw through the mounting plate aligning the ribs on the screw with the slots on the mounting plate.
  • Page 8 0313-7201-00_(PWFPH_B_L)_PEUK_V10.qxp:_ 2015.12.3 2:55 PM Page 7 6. ACTIVATING THE ALARM This alarm is automa cally ac vated when it is a ached to the moun ng plate for the first me. Once ac vated, the ba ery will power the alarm for its 10-year life under normal condi ons. Align the alarm with the moun ng bracket and rotate clockwise approximately 45 degrees un l the unit stops rota ng and clicks into place.
  • Page 9 0313-7201-00_(PWFPH_B_L)_PEUK_V10.qxp:_ 2015.12.3 2:55 PM Page 8 7. OPERATING AND TESTING YOUR SMOKE ALARM Sound Emitted Voice Prompt LED (all) & Escape Light Note (Model WFPV) (Model WFPL) Normal None None Flashes once every 10 minutes LED will flash every 60seconds for 10 Operation minutes after power-up, then flashes every 10 minutes...
  • Page 10: Maintenance

    0313-7201-00_(PWFPH_B_L)_PEUK_V10.qxp:_ 2015.12.3 2:55 PM Page 9 8. MAINTENANCE At least once a year remove the alarm and use a vacuum cleaner to suck out any dust. Wipe the outside of the alarm with a damp cloth. When you replace the alarm remember to test it. •...
  • Page 11 0313-7201-00_(PWFPH_B_L)_PEUK_V10.qxp:_ 2015.12.3 2:55 PM Page 10 9. PRODUCT SPECIFICATION Power Sealed lithium ba ery Sensors Smoke - Op cal 0 ° C to 40 ° C Opera ng Temperature Range Humidity Opera ng Range Up to 93%RH (non-condensing) -20 ° C to +65 ° C, 5-95%RH (non-condensing) Storage and Transport Condi ons Alarm Sound...
  • Page 12 0313-7201-00_(PWFPH_B_L)_PEUK_V10.qxp:_ 2015.12.3 2:55 PM Page 11 10. DEACTIVATION OF ALARM WARNING! • Deac va on of the alarm is permanent. Once the alarm has been deac vated, it cannot be reac vated! • Once deac vated, the alarm will NO LONGER DETECT SMOKE. •...
  • Page 13: Service And Warranty

    Kidde Safety warrants to the original purchaser that the enclosed smoke alarm will be free from defects in material and workman- ship or design under normal use and service for a period of 10 (ten) years from the date of purchase. The obliga on of Kidde Safety Europe Limited under this warranty is limited to repairing or replacing the smoke alarm or any part which we find to be de-...
  • Page 14 0313-7201-00_(PWFPH_B_L)_PEUK_V10.qxp:_ 2015.12.3 2:55 PM Page 13 Essential characteristics Performance EN14604:2005 Clause Nominal activation conditions/Sensitivity. 4.12, 5.2, 5.3, 5.4, 5.5, PASS Response delay (response time) and 5.15, 5.17, 5.18, 5.20 Performance under fire condition 4.1, 4.2, 4.5, 4.6, 4.7, 4.8, 4.9, 4.10, Operational reliability 4.15, 4.16, 4.17, 4.19, 5.11 PASS...
  • Page 15: Environmental Protec On

    Check with Local Authority or retailer for recycling advice. QUESTIONS OR FOR MORE INFORMATION Call our Consumer Hotline at 0800 917 0722 or contact us at our website at www.kiddesafetyeurope.co.uk Kidde Safety Europe Limited, Mathisen Way, Poyle Road, Colnbrook, Berkshire SL3 0HB P/N: 0313-7201-00...