Control Circuit Board
4-2
Time Chart
No
Item
2
Motor lock speed
High (H)
Medium (M)
(M1)
(M2)
Low (L)
(L1)
7
Fan motor control
High (H)
Medium (M)
Low (L)
8
Overheat protector
Abnormal overheat
detection
9
Power
failure
system
10
Segment safety display
H E A T I N G
H E A T I N G
Specification
When motor lock is detected during combustion, shift
to extinguishing process and stop operation.
A:1144 ±1.4%rpm
Display E- 8.
B:1259 ±1.4%rpm
A:1030 ±1.4%rpm
B:1030 ±1.4%rpm
A:1030 ±1.4%rpm
B:1030 ±1.4%rpm
A:1030 ±1.4%rpm
B:1030 ±1.4%rpm
A: 687 ±1.4%rpm
B: 687 ±1.4%rpm
A: not detected
B: not detected
A:Full wave
B:Full wave
A:5 : 1 (ON : OFF)
B:3 : 1 (ON : OFF)
A:2 : 1 (ON : OFF)
B:1 : 3 (ON : OFF)
When normal
ON
When
electromagnetic
extinguishing process and stop operation.
When abnormal
Display E- 12.
overheat is detected
recovery
More than 30 minutes
Keep in memory of current time, set timer time, set
room temperature, timer operation and power saver
operation during power failure.
E- 0
Power failure
E- 2
Miss ignition
E- 6
Miss flame
E- 8
Motor lock
E-12
Recovery after overheat protector operated
E-13
Burner thermistor trouble detection
E-22
When an ignition error has occurred 3 times in succession
E-23
Primary flame (Flame sensor) is malfunction
S Y S T E M S
S Y S T E M S
Trouble Shooting
Conditions
abnormal
overheat
is
detected
during
pump
operation,
shift
Remarks
to