INDOOR INSTALLATION GUIDELINE

1
• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the drilling
points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting plate retention spots and dimensions
INDOOR UNIT ATXC20/25/35/50
Recommended mounting plate
retention spots (7 spots in all)
117
Ø 65
4
9
5 .
170
INDOOR UNIT ATXC60/71
Recommended mounting plate
retention spots (7 spots in all)
117
Ø 65
49.5
170

INSTALLING THE MOUNTING PLATE

 Mounting plate
 Mounting plate
fixing screw
Place a leveler
on these tabs.
5
0
770
Place a leveler
on these tabs.
60
990
1-12
The  mounting plate
should be installed
on a wall which can
support the weight of
the indoor unit.
Use a tape measure as
shown.
Position the end of the
tape measure at
116.5
Ø 65
170
49.5
All dimensions are in mm
Use a tape measure as
shown.
Position the end of the
tape measure at
126.5
Ø 65
170
65.5
All dimensions are in mm
Through-the-wall hole
Ø 65mm
Drain hose position
unit : mm
Through-the-wall hole
Ø 65mm
Drain hose position
unit : mm