4.2 Infrared (IR) Learn Function – Reset
While in IR Learning mode, by pressing the same learnable key twice, the key will revert to default
(i.e. no code).
The user shall also be able to reset all the 5 keys to the default setting.
This is done by pressing the "VOL-" key and "SCROLL-" key simultaneously for 3 seconds. SYSTEM
POWER key will turn ON and user has to release all keys. The RC starts erasing all learned data and
returns to its original settings; i.e. before any learning was performed. Upon successful erasure,
SYSTEM POWER LED will give 2 slow blinks, otherwise 3 fast blinks to indicate failure.
4.3 Infrared (IR) Database
Follow the key sequences below to invoke the Database Programming feature to program a codeset
for a particular brand of TV:
Step
Database Programming Sequence
1
Turn on the TV device.
2
Press and hold "SCROLL+" and "SCROLL-" keys for 3 seconds. SYSTEM POWER LED stays
ON; RC enters Database Programming mode. Release the keys.
3
Database Scanning
Aiming the remote control at the TV device IR receiving opening, press and hold "UP" key to
transmit PowerToggle IR command for the (n+1) universal codeset in the codeset list, where n
is the programmed TV codeset prior to Database Programming mode. If there is no TV codeset
programmed, the first codeset in the list will be transmitted. During transmission of the IR
command, the TV POWER LED will turn ON. When the IR transmission completes for the
codeset under scan, the TV POWER LED will turn off and no new IR command will be sent over
the next 1.5 seconds approximately. If the TV does not turn off, the user will need to keep
pressing the "UP" key and the remote control will then try the next universal codeset in the list.
4
When the TV turns off, the user shall release the "UP" key to stop IR transmission.
The user can now try pressing each of the 5 IR keys to check if the underlying IR codes works
with the TV device.
At this point, the user can select to proceed with the following steps:
1. Continue Database scanning – Step 3
2. Step codeset Forward – Step 5
3. Step codeset Backward – Step 6
4. Program codeset into RC and Exit – Step 7
5. Exit – Step 8
5
Step codeset Forward
Press and hold "RIGHT" key. This will step to the next codeset where it has left off. The
PowerToggle IR command will be transmitted as long as the key is pressed. When user release
and press "RIGHT" key again, the PowerToggle IR command of the next codeset will be
transmitted.
6
Step codeset Backward
Press and hold "LEFT" key. This will step to the previous codeset where it has left off. The
PowerToggle IR command will be transmitted as long as the key is pressed. When user release
and press "LEFT" key again, the PowerToggle IR command of the previous codeset will be
transmitted.
7
Program codeset into RC and Exit
Press and release "OK" key. The codeset from the last transmitted IR commands will be
programmed into RC. Upon completion, the SYSTEM POWER LED will give 2 slow blinks to
indication success, otherwise, 3 fast blink to indicate failure and exits to normal mode.
8
Exit
Press and release "BACK" key. No codeset will be programmed into RC. No LED indication will
be given and the RC exits to normal mode.