Download Print this page

American Standard Selectronic 6062.013 Installation Instructions Manual page 6

Hard-wired ac powered proximity urinal flush valve 0.125 0.25 0.5 & 1.0 gpf, exposed flushometer for 3/4" top spud urinals

Advertisement

INSTALL THE SWEAT SOLDER
4
ADAPTER; Fig. 5
Turn water supplies off
CAUTION
before beginning
Note: Install Optional Sweat Solder Adapter
(Supplied) for copper pipe supply line. Fig. 5.
1. Measure the distance (A) from the finished wall to the
center of the inlet spud on the fixture.
2. Cut the supply pipe 1-1/4" (A-B=C) shorter then the
measurement taken in Step 1. File any rough edges off
the end of the supply pipe.
3. Clean the end of the supply pipe. Push the threaded
Adapter on until it is seated against the internal stop.
Sweat the Adapter to the pipe.
INSTALL COVER TUBE, WALL
5
ESCUTCHEON and SUPPLY STOP;
Fig. 6
1. Measure from finished wall to first thread of Adapter
or threaded supply pipe (dimension "X"). Cut
COVER TUBE (1) to length (X). Apply Teflon Tape to
the threaded end of the Adapter or supply pipe. Fig. 6a.
2. Push the COVER TUBE (1) into the WALL ESCUTCHEON
(2). Slide both onto the SUPPLY PIPE (3). Fig. 6b.
3. Push the COVER TUBE (1) in to expose the threads of
the supply pipe. Fig. 4c. With a wrench thread the
SUPPLY STOP (4) onto the SUPPLY PIPE (3). Align and
tighten. Fig. 6c.
4. Pull COVER TUBE (1) against SUPPLY STOP (4) and
push WALL ESCUTCHEON (2) against finished wall.
INSTALL DOWN TUBE AND
6
VACUUM BREAKER; Fig. 7
1. Place the SPUD FLANGE (1) over the spud on
the Fixture.
2. Thread SPUD COUPLING NUT (2) onto Spud.
Make sure SEAL WASHER (3) and FRICTION
WASHER (4) are installed. Do not tighten fully.
3. Insert the DOWN TUBE (5) into the SPUD
COUPLING NUT (2) and push it down.
Note: If cutting Down Tube (5) to size, note that
Critical Line (C/L) on Vacuum Breaker must
typically be 6" (152mm) above fixture. Consult Code
for details.
Fig.5
FINISHED WALL
A
(A-B)=
C
FILE EDGES
CLEAN
ADAPTER
Fig. 6
Fig. 6a
Fig. 6b
3
Fig. 6c
1
Fig. 7
5
2
1
5
CENTER LINE OF
FIXTURE SPUD
B
32mm
(1-1/4")
SOLDER
ADAPTER
FINISHED WALL
X
TEFLON TAPE
2
2
X
4
3
4
3/4" TOP SPUD
M965218 REV 1.8
1

Advertisement

loading