Interconnect Drawings - Garmin GDL 82 Installation Manual

Hide thumbs Also See for GDL 82:
Table of Contents

Advertisement

10 Interconnect Drawings

Figure 10-1
Typical Installation ......................................................................................................................... 10-2
Follow each note relevant to its figure. Each figure contained in this section has notes that must be followed. General
notes apply to all of the figures contained in this section.
General Notes
Unless specified differently, all wires 24 AWG or larger.
Power and ground connections are 22 AWG wire.
Separate grounds and wiring routings in case of wiring or grounding system failure.
Designations for ground connections are as follows.
Shield Block Ground
S
Shield ground terminations to the connector backshell must be 3.0 inches or less in length.
Interfaced equipment shown with aircraft frame ground designation is where the actual grounding method is
unknown.
Grounding method may be either shield ground or frame ground depending on specific equipment terminations.
190-01810-00
Rev. 5
Airframe Ground
Interconnect Drawings
GDL 82 TSO Installation Manual
Page 10-1

Hide quick links: