Download Print this page

Daikin 2MKS70JVLT Service Manual page 8

Removal procedure, outdoor unit, inverter, multi type, cooling only/heat pump, 7.0/8.0/9.0/10.0 kw class, 24000/32000 btu/h class

Advertisement

Removal of Outer Panels
Step
3
Remove the right side
panel.
4. Remove the front panel
(2).
Remove the 2 screws.
1
Slide the front panel (2)
2
downward to unfasten
the hook.
6
Procedure
Front Panel (2)
Front
Panel (1)
The US model has a service
lid on the stop valve
mounting plate.
Remove the 2 screws to
remove the service lid.
The US model has a conduit
mounting plate.
(R10441)
Knockout hole
This screw is M5 × 16
(R10629)
(R10374)
Si121176
Points
Service lid
Screw
(R10372)
Lock nut
Conduit
mounting plate
Conduit
(R17351)
Removal Procedure

Advertisement