Removal of Coils / Thermistors
Step
2
Peel off the putty and
pull out the liquid pipe
thermistors.
Pull out the outdoor
3
heat exchanger
thermistor.
28
Procedure
Outdoor heat exchanger
thermistor
Liquid
pipe
thermistor
(R17413)
Be careful not to lose the
fixtures for the thermistors.
Liquid pipe
thermistor
Fixture
(R6450)
(R10541)
Si121176
Points