If A Problem Occurs - Sennheiser MK 4 Instruction Manual

Sennheiser microphone user manual
Hide thumbs Also See for MK 4:
Table of Contents

Advertisement

If a problem occurs ...

If a problem occurs ...
Problem
No function
No signal
transmission
14 |
MK 4
Possible cause
The phantom power
on the mixing con-
sole or phantom
power device is not
switched on.
The phantom power
device is not con-
nected to the mains
or no battery is
inserted.
The microphone is
connected to the
wrong microphone
amplifier input of
the subsequent
device.
Possible solution
Check the corresponding
setting on the channel
strip.
Check the mains connec-
tion or the battery of the
phantom power device.
Check the signal path.
If necessary, activate the
appropriate input on the
corresponding channel
strip of the mixing
console.