Installation, Operation and Maintenance Manual
Please read and save these instructions for future reference. Read carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property damage!
Constant Pressure Control
Constant pressure control is a packaged system
specifically designed to control a fan with a Vari-
Green motor. The controller has two major modes;
controlling pressure on the fan inlet, exhaust
control; and controlling pressure on the fan outlet,
pressurization control. Exhaust control has a cutout
feature that shuts off the fan when there is no
demand on the system. In both modes closing an
override input sets the fan to a constant speed.
The system includes a fan with Vari-Green motor,
pressure tap, and controller. The system is designed
with considerations for lint laden air. Performance
ranges from 500-3000 CFM and up to ±1 inch of
pressure. Fan models available are G, CUE, CW,
and SQ. Each system shall bear a manufacturer's
nameplate.
General Safety Information
Only qualified personnel should install this product.
Personnel should have a clear understanding of
these instructions and should be aware of general
safety precautions. Improper installation can result
in electric shock, possible injury due to coming in
contact with moving parts, as well as other potential
hazards. Other considerations may be required
if high winds or seismic activity are present. If
more information is needed, contact a licensed
professional engineer before moving forward.
DANGER
Always disconnect, lock and tag power source before
installing or servicing. Failure to disconnect power
source can result in fire, shock or serious injury.
CAUTION
When servicing the fan, motor may be hot enough
to cause pain or injury. Allow motor to cool before
servicing.
CAUTION
Precaution should be taken in explosive
atmospheres.
Vari-Green Control
Constant Pressure
Follow all local electrical and safety codes, as well
as the National Electrical Code (NEC) and the
National Fire Protection Agency (NFPA). Where
applicable, follow the Canadian Electric Code.
1. The rotation of the wheel is critical. It must be
free to rotate without striking or rubbing any
stationary objects.
2. Motor must be securely and adequately
grounded.
3. Do not spin fan wheel faster than maximum
cataloged fan RPM. Adjustment to fan speed
significantly affects motor load. If fan RPM is
changed, motor current should be checked
to make sure it is not exceeding the motor
nameplate amps.
4. Do not allow the power cable to kink or come
in contact with oil, grease, hot surfaces,
or chemicals. Replace cord immediately if
damaged.
5. Verify that the power source is compatible with
the equipment.
6. Never open access doors to a duct while the fan
is running.
PN 474766
1

Advertisement

Table of Contents
loading

Summary of Contents for Greenheck Vari-Green Control

  • Page 1 PN 474766 Vari-Green Control Constant Pressure Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.
  • Page 2 Forming a drip loop in the tubing just before it enters stored indoors in a clean, dry atmosphere. the Greenheck Constant Pressure Controller is good practice. (The distance from the bottom of the loop Remove any accumulations of dirt, water, ice, or to the controller’s pressure port should be one to two...
  • Page 3: Electrical Box

    It is best to mount the wall static pressure pickup port using an electrical box. A simple hole in the wallboard may be used, but in any case be sure that the foam gasket on the back of the pickup seals tightly against the wall Electrical Box Mount Electrical Box...
  • Page 4: Constant Pressure Control

    • Mount the Constant Pressure Control in the Wall Mount vertical position with the tubing connectors in the down position. • One Duct Tap – Maintains constant pressure in duct based upon space pressure where the Mounting Plate Constant Pressure Control is mounted – Connect the “H”...
  • Page 5: Controller Operation

    Controller Operation The Constant Pressure Control has three buttons accessible through the lid: Enter, Up or Increase (▲), and Down or Decrease (▼). Additionally on the circuit board inside the lid is jumper J5. J5 is used to set the controller into normal operation, RUN, or programming mode, PROG.
  • Page 6: Parameter Descriptions

    It is recommended that you Auto zero sets the zero pressure reading of the make sure your pressure set point is correct before controller. Greenheck recommends performing auto continuing. zero after installation and before first operation.
  • Page 7: Wiring Diagram

    Exhaust fans use inlet control. Supply fans use See parameter P06 for operational details. outlet control. Inline fans may use either inlet or outlet control. Wiring Diagram Copyright 2011 © Greenheck Fan Corp. 474766 • Constant Pressure Control, Rev. 1, April 2011...
  • Page 8: Troubleshooting

    Lower the value and observe the operation of the system. Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the shipment date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid.