How To Install The Access Easy Controller 2.1; Preliminary; Mounting The Panel On A Concrete Wall - Bosch Access Easy Controller 2.1 Hardware Installation Manual

Table of Contents

Advertisement

58
en | How to Install the Access Easy Controller 2.1
11

How to Install the Access Easy Controller 2.1

11.1

Preliminary

1.
2.
Notice!
If the AEC2.1 is going to be directly connected to a host computer on its own private
network, and not to the customer's company network, then the controller's default IP address
setting (192.168.0.41) can be used.
3.
11.2

Mounting the Panel on a Concrete Wall

This section addresses the mounting of the AEC2.1 panel. For mounting always use hardware
and materials appropriate to the nature of the surface upon which the panel is mounted. The
following instructions describe the basic steps to mount the panel on a concrete wall.
Warning!
For mounting always use hardware and materials appropriate to the nature of the surface
!
upon which the panel is mounted. If in doubt, consult a certified technician.
1.
2018.11 | 1.0.6 | F.01U.122.796
You will need to obtain the mounting location details from the customer before the
controller can be installed.
The mounting location of the controller should provide:
protection from unauthorized access
protection from accidental damage
(ideally) an uninterruptable power supply
protection from electrical interference
an environment temperature range of 0°C - 50°C
an environment humidity of 5% ~ 85% +/-5% RH
a network connection point - either a wall jack or an available hub where a category
5 cable can be plugged in, to provide the AEC2.1 with access to the customer's
network.
The customer will also need to provide some additional information before the controller
can be made operational.
An IP address for the controller
The subnet mask to be used by the controller.
If a gateway is used by the customer's network, then obtain the gateway address to
be used by the controller.
E-mail server IP address, port number, and domain name (required only if the
customer intends to use the controller's e-mail notification services).
Location of an analog telephone line (required only if a dial-in connection will be
used).
For a UL-compliant installation, adhere to the following installation guidelines:
The controller must be installed in the same room as the network jack or hub.
After acquiring the exact mounting location, mark out the exact position of the mounting
holes.
Place the panel against the wall, over the area where the panel is to be mounted.
Hardware Installation Manual
Access Easy Controller 2.1
Robert Bosch (SEA) Pte Ltd

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aec-aec21-ext1Apc-aec21-ups1

Table of Contents