Raypak BACnet Interface Module Installation And Operation Manual
Raypak BACnet Interface Module Installation And Operation Manual

Raypak BACnet Interface Module Installation And Operation Manual

Adds bacnet mstp capability to temptracker mod+ hybrid controls

Advertisement

Installation and Operation Manual
adds BaCnet MSTP Capability to
TempTracker mod+ Hybrid Controls
OUTPUT RATINGS:
120VAC, 6A RESISTIVE
1A PILOT DUTY, 15A TOTAL
FOR ALL CIRCUITS
INPUT RATINGS:
115VAC 60Hz , 30VA MAX
USE COPPER WIRE,
CLASS 1 WIRE ONLY.
ENCLOSED
ENERGY
MANAGEMENT
EQUIPMENT
99RA
CAUTION
: RISK OF ELECTRIC SHOCK
More than one disconnect switch may be required
to de-energize the equipment before servicing.
PWR
SYS
A
B
C
D
L N
1 2
3 4 5 6 7 8 9 10 11 12
This raypak control is strictly an operating control; it should never
be used as a primary limit or safety control. all equipment must have
its own certified limit and safety controls required by local codes.
The installer must verify proper operation and correct any safety
problems prior to the installation of this raypak control.
Cat.# 5000.71
05/01/11
HYBRID
SYSTEM
A
B
C
D
DO NOT APPLY ANY VOLTAGE
PROGRAM
RUN
TO INPUT TERMINALS
A
B
C
D
SHUTDOWN
OUTDOOR
SYSTEM
PROVE
/TSTAT
CUR / VLT
CUR / VLT
CUR / VLT
CUR / VLT
TEMP
TEMP
/DHW
/SETBACK
GND
mA
VLT
GND
mA
VLT
GND
mA
VLT
GND
mA
mA
VLT
T
O
T
O
O
-
-
-
-
+
+
+
+
+
+
+
+
+
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30 31
WarnIng
BACnet
Interface Module
EXTENSION
To BACnet
MODULE
O
RS-485
32
RJ45 Communication Cable
BACnet Interface Module
MSTP
PRODUCT
RS485
A GND B
COMM
1
2
3
MSTP
P/N 241441 REV.1

Advertisement

Table of Contents
loading

Summary of Contents for Raypak BACnet Interface Module

  • Page 1 30 31 RJ45 Communication Cable WarnIng This raypak control is strictly an operating control; it should never be used as a primary limit or safety control. all equipment must have its own certified limit and safety controls required by local codes.
  • Page 2: Table Of Contents

    WIrIng TO COnTrOL anD exTenSIOn . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 BaCnet Interface Module Installation and Configuration Manual...
  • Page 3: Overview

    • RJ45 cables (Ethernet Cable), InSTaLLaTIOn The BACnet Interface Module communicates with the Raypak Hybrid control using the RJ45 cable. Thus, it needs to be installed in close proximity to the control. • Mount the BACnet Interface Module on a flat surface next to the control.
  • Page 4: Connecting To Control

    RJ45 Communication Cable Connecting to Control • The BACnet Interface Module communicates all of its information to the control using RJ45 cable (the cable is provided with the module). • Both the BACnet Interface Module and the control have RJ45 sockets.
  • Page 5: Bacnet Startup Menu Setup

    A GND B COMM and the control. Green LED Flashes on communication between the BACnet Interface Module and the BACnet network. Red LED Flashes steadily to indicate the BACnet Interface Module is operational. BaCnet Interface Module Installation and Configuration Manual...
  • Page 6: Troubleshooting

    LeD Lights • The RJ45 connection to the control powers the BACnet Interface Module. If all LEDs are off, then check the cable connecting the module to the control. The cable consist of 8 wires. Check each of the color-coded wires continuity in the cable using a continuity meter.
  • Page 7: Wiring To Control And Extension

    Ext B EXTENSION MODULE CUR / VLT CUR / VLT CUR / VLT CUR / VLT CUR / VLT CUR / VLT RS-485 9 10 11 12 11 12 RJ11 RJ11 Extension Cable BaCnet Interface Module Installation and Configuration Manual...
  • Page 8 Raypak, Inc . 2151 Eastman Ave ., Oxnard, CA 93030 PH: (805) 278-5300 FAX: (805) 278-5468...