• Status Displays
The BDA Controller's Display normally shows one of 4 Status Displays. Pressing the Adjust Buttons sequences
through the 4. Pressing the Select Button from any status screen enters the Main Menu. Pressing the Exit Button
does nothing, except when a Fault condition exists and Exit Button clears the fault. If a Fault occurs, the display
switches to the Master Status display and shows a text message for the Fault(s).
Current Monitor Status
This Screen displays the current drawn by each Booster and PA in the system. The top row shows abbreviated
names for the amplifiers, the bottom row shows the current being drawn by each module. Entries for modules
disabled by another module's fault show "Dsbl". Entries for modules that are manually disabled are blank. Modules
that have a fault have their current indication blinking. If an overcurrent has occurred, then the word "Over" appears
instead of a number.
Up-B Up-P Dn-B Dn-P
0.65 Over 0.60 2.35
Thermal Monitor Status
This Screen shows current temperature fan and battery status. Temperature readout is in degrees Celsius. If an
over-temperature condition exists, temperature will flash. Each fan has an indication of On, Off or Fail. Battery
voltage is displayed in volts to a resolution of 10 mV. If battery is not installed, display says "None" Battery voltage
flashes if it is low.
Temp FanA FanB Batt
53C ON
AGC Status
This Screen displays data about AGC operation and current gain setting. If AGC is disabled, then the readout for that
direction shows "Off" (*). If AGC is enabled, but input signal is below minimum input level for AGC action, readout
shows "Ok". If AGC is enabled, and AGC is acting, then readout shows equivalent single carrier input level for that
direction in dBm. (*) If AGC is enabled, and amplifier is overdriven, readout shows blinking "Over" (*).
GN-UP-AGC GN-DN-AGC
65dB Dsbl 78dB 23dB
Master Status
This Screen shows normally ;
BDA OK
If a Fault occurs, then a display such as ;
Fault!
Overtemperature
Will be shown.
l Page 10
Fail 26.25
Kaval Telecom Inc.