Technical data

Note
Always use product in accordance with specifications.
7.1

Power

● 100 ... 240 V AC ± 10 %, 50/60 Hz, 15 VA
Fuse: 5 x 20 mm, Slow Blow, 1A, 250 V
7.2

Performance

Repeatability
● ± 1 %
Temperature coefficient (setpoint variance)
● 0.018 %/°C (0.01 %/°F)
Setpoint adjustment range
● 2 ... 3 000 ppm (pulses per minute): standard model
● 0.15 ... 15 ppm: slow speed version
Dynamic range
● 0 ... 7 200 ppm
Milltronics MFA 4p
Operating Instructions, 08/2017, A5E33988839_AB
7
27