Specification Chart - Sears 176 Owner's Manual

Sears air compressor user manual
Table of Contents

Advertisement

AREA
Toxic Vapors
Compressed
Air
HAZARD
i i
,
......
Compressed
air from this unit
may cenlain
poisonous carbon
monoxide.
Certain sprayed materials Such
as paints, weed
killer, sand, in-
secticides,
etc., may be harmful if
used in a closed area or if inhaled.
Compressed air may propel dirt,
metal shavings, etc. and result in
possible injury.
SAFEGUARDS
illl,
Never directly inhale the compressed air
produced by this unit.
Be certain to read labels when spraying
paints or poisons.
Use a mask or respirator whenever there is a
chance that you might inhale anything that
you are spraying.
Read all instructions so
that you know that your mask will protect you
from what you are spraying.
iiiiii
Jlll,lllllll
SPEC RCATIO.
C, RT
J_JUULII
II
I,II,,,
IIIIII
.
..........................................
Model
No.
919.176210
919,176311
Never point any nozzle or sprayer toward a
person or any part of the body.
Always wear safety goggles or glasses when
spraying.
IIIII
_
iiiii
................
i,ii1,1 iii
919.176320
"
919,176330
HP
Displacement CFM
Bore
Stroke
Voltage-Single
Phase
Branch Circuit Min, Requirements
2
3
11.7
14.0
23/,=-
27/e-
2"
2"
220-24.0
220-240
15 amp
15 amp
1
1
9.2
9.2
2_/= "
2_/,,,
2"
2"
"110-220
"110-220
20 amp
15 amp
"Fuse
Type
"Fusetron" Type T
"Fusetron" Type T
Amperage
at Max Pressure
19.5
15.5
Air Tank Capacity
12 gel
12 gal ASME
Approximam
Cut-in Pressure
-'80"
psig
B0 psig
Approximate
Cut-out
Pressure
100 psig
100 psig
SCFM
at 125 psig
_
-
100 psig
f
5.6
5.6
90 psig
6.0
6.0
40 psig
7.3
73
II,ILUU_
............
i
I
II
IIIIIIIII
ii
"Fusetron" Type T
"Fusetron" Type T
12.4
14.4
20 gel ASME
30 gal ASME
100 psig
100 psig
125 psig
125 psig
6,4
75
m
7.5
8.5
9.0
10.3
Jill
lUll
"Models 919.176210 & 919.176311, 1 HP motor is dual voltage, 110-!20 and 220-240 volt, It is wired for 110-120 voltbut can be converted to
220.240 volt operation. Instructions for connecting the motor for operation at 220-240 volt can be found printed on the inside of the
motor cover or on the nameplate of motor.
"A c/muir breaker is also acceptable.
MODEL #919.178311 (1 HP) air compressor
can be oper-
ated on a 15 amp circuit provided
the following conditions
exist:
t) Voltage supply to circuit Is normal,
2) Circuit Is not used to supply any Other electrical
needs
(appliances,
lights, etc,)
3) Extension cords comply
with specifications
in manual.
4) Circuit Is equipped
with 15 amp circuit breaker or 15
amp "'Fusetron" Type T time delay fuse.
If any of the above conditions
cannot
be met or If the
operation
of the compressor
repeatedly
cause interrup-
tion of the power J! may be necessary
to operate It from a
20 amp circuit.
When converting
1 HP models
to 220-240 volt operation,
the attached
three-prong
110-120 volt plug must be
replaced with a three-prong
220-240 volt plug (purchase
loCally) or order line ©ord Part No. SUDL-404-1.
SCFM (Standard Cubic Feet per Minute):
Unit of measure of air delivery
PSIG (Pounds per Square inch Gauge):
Unit of measure of pressure

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents