Acoustics; Electromagnetic Immunity - Seagate SV35.3 Series Serial ATA ST3250310SV Product Manual

Sv35.3 series serial ata
Hide thumbs Also See for SV35.3 Series Serial ATA ST3250310SV:
Table of Contents

Advertisement

2.10

Acoustics

Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-
surements are consistent with ISO document 7779. Sound power measurements are taken under essentially
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.
Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined
by the following equation:
(Number of seeks per second = 0.4 / (average latency + average access time)
Table 4:
Fluid Dynamic Bearing (FDB) motor acoustics
ST31000340SV
ST3750330SV
ST3500320SV
ST3250310SV
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and
power to operational levels.
2.11

Electromagnetic immunity

When properly installed in a representative host system, the drive operates without errors or degradation in
performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 5:
Radio frequency environments
Test
Description
Electrostatic
Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV
discharge
Radiated RF
80 to 1,000 MHz, 3 V/m,
immunity
80% AM with 1 kHz sine
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
Electrical fast
± 1 kV on AC mains, ± 0.5 kV on external I/O
transient
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
Conducted RF
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine A
immunity
Voltage dips,
0% open, 5 seconds
interrupts
0% short, 5 seconds
40%, 0.10 seconds
70%, 0.01 seconds
SV35.3 Series Serial ATA Product Manual, Rev. B
Idle*
2.7 bels (typ)
2.9 bels (max)
2.5 bels (typ)
2.8 bels (max)
CE Seek
2.8 bels (typ)
3.0 bels (max)
2.6 bels (typ)
2.8 bels (max)
Performance level
Reference standard
B
EN 61000-4-2: 95
A
EN 61000-4-3: 96
ENV 50204: 95
B
EN 61000-4-4: 95
B
EN 61000-4-5: 95
EN 61000-4-6: 97
C
EN 61000-4-11: 94
C
C
B
17

Advertisement

Table of Contents