Physical/Electrical Specifications; Ac Power Requirements; Dc Power Requirements - Seagate Cheetah ST336605FC/FCV Product Manual

Seagate cheetah 73lp fc disc drive product manual
Table of Contents

Advertisement

Cheetah 73LP FC Product Manual, Rev. D
6.0

Physical/electrical specifications

This section provides information relating to the physical and electrical characteristics of the drive.
6.1

AC power requirements

None.
6.2

DC power requirements

The voltage and current requirements for a single drive are shown below. Values indicated apply at the drive
connector.
Table 1:
DC power requirements
Voltage
Regulation
Avg idle current DC
Maximum starting current
(peak DC) DC
(peak AC) AC
Delayed motor start (max) DC 3σ
Peak operating current:
Typical DC
Maximum DC
Maximum (peak) DC
[1]
Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these val-
ues. Power supply at nominal voltage. N = 6, 22 Degrees C ambient.
For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching
[2]
10,000 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been
completed and that the drive is able to accept selection by the host initiator.
[3]
See +12V current profile in Figure 3.
[4]
This condition occurs when the Motor Start option is enabled and the drive has not yet received a Start
Motor command.
[5]
See paragraph 6.2.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and
transient response.
[6]
Operating condition is defined as random 8 block reads at 200 I/Os per second. Current and power speci-
fied at nominal voltages. Decreasing +5 volt supply by 5% increases 5 volt current by 3.6%. Decreasing
+12 volt supply by 5% increases 12 volt current by 3%.
[7]
During idle, the drive heads are relocated every 60 seconds to a random location within the band from
track zero to one-fourth of maximum track.
General DC power requirement notes.
1. Minimum current loading for each supply voltage is not less than 1.5% of the maximum operating current
shown.
2. The +5V and +12V supplies should employ separate ground returns.
3. Where power is provided to multiple drives from a common supply, careful consideration for individual drive
power requirements should be noted. Where multiple units are powered on simultaneously, the peak start-
ing current must be available to each device.
ST373405FC
Notes
(Amps)
+5V
[5]
±5%
X [1] [7]
0.85
3σ [3]
0.89
3σ [3]
1.20
[1] [4]
0.76
X [1] [6]
0.88
3σ [1]
0.95
1.39
ST336605FC
(Amps)
(Amps)
+12V [2]
+5V
±5% [2]
±5%
0.58
0.85
2.38
0.92
4.02
1.24
0.04
0.75
0.87
0.88
0.97
0.93
2.51
1.41
(Amps)
+12V [2]
±5% [2]
0.44
1.66
3.03
0.04
0.81
0.89
2.35
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents