General Information

General Specifi cations
Table 1 – Burner Specifi cations
Capacity
Firing rate: - 0.40 – 1.75 GPH
Input: Min. - 56,000 Btu
Max - 245,000 Btu
Certifi cation/
UL certifi ed to comply with ANSI/UL296 &
Approvals
tested to CSA B140.0
Fuels
U. S No. 1 or No. 2 heating oil only (ASTM
Canada No. 1 stove oil or No. 2 furnace oil
Electrical
Power supply - 120 volts AC, 60 Hz, single
phase
Operating load - 5.8 Amps max
Motor - 1/7 hp, 3450 rpm, NEMA 48M
frame PSC rotation CCW when
facing shaft end
Ignition - Continuous duty solid-state igniter
Fuel pump
Outlet pressure - Note 1
Air tube
ATC code - See Table 2
Dimensions
Height (maximum) - 12-1/2 inches
(with cover)
Width (maximum) - 15 inches
Depth
Air tube diameter
*
Note 1. See appliance manufacturer's burner specifi cations for
recommended outlet pressure.
Table 2 – Air Tube Combinations (ATC)
Firing rate
Head
(gph)
(min-max)
0.40-1.00
9-Slot
0.40-1.00
6-Slot
0.40-1.35
9-Slot
0.40-1.35
6-Slot
1.10-1.75
9-Slot
1.10-1.75
6-Slot
Figure 1. Burner label location
Page 4
D396)
only
- 9-1/4 inches
- 3-1/4 inches
ATC codes for usable air tube
lengths:
5"
7"
NX50LG
NX70LG
NX90LG
NX50LH
NX50LH
NX90LH
NX50LB
NX70LB
NX90LB
NX50LC
NX70LC
NX90LC
NX50LD
NX70LD
NX90LD
NX50LF
NX70LF
NX90LF

Notice Special Requirements

For recommended installation practice in Canada,
refer to the latest version of CSA Standard B139 &
B140.
Concealed damage — If you discover damage to
the burner or controls during unpacking, notify the
carrier at once and fi le the appropriate claim.
When contacting Beckett for service information —
Please record the burner serial number (and have
available when calling or writing). You will fi nd the
serial number on the silver label located on the left
rear of the burner. Refer to Figure 1.

Inspect/Prepare Installation Site

Clearances to Burner and Appliance

Provide space around burner and appliance for
ease of service and maintenance. Check the mini-
mum clearances against those shown by the ap-
pliance manufacturer and by applicable building
codes.

Inspect Chimney or Direct Vent System

WARNING
!
Failure to provide adequate air supply could se-
9"
riously affect the burner performance and result
in damage to the equipment, asphyxiation, ex-
plosion or fi re hazards.
The burner cannot properly burn the fuel if it is not
supplied with a reliable combustion air source.
Follow the guidelines in the latest editions of the
NFPA 31 and CSA-B139 regarding providing ad-
equate air for combustion and ventilation.
Inspect the chimney or vent. Make sure it is prop-
erly sized and in good working condition. Follow the
instructions supplied by the appliance manufactur-
er.