Summary of Contents for Contec FA-UNIT-F6BE/2U

  • Page 1 SBC Series Full Size 6-slots 2U Chassis FA-UNIT-F6BE/2U User’s Manual CONTEC CO.,LTD.
  • Page 2: Check Your Package

    Check Your Package Thank you for purchasing the CONTEC product. The product consists of the items listed below. Check, with the following list, that your package is complete. If you discover damaged or missing items, contact your retailer. Product Configuration List - Chassis [FA-UNIT-F6BE/2U]…1...
  • Page 3: Copyright

    No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO., LTD. CONTEC CO., LTD. makes no commitment to update or keep current the information contained in this document. The information in this document is subject to change without notice.
  • Page 4: Table Of Contents

    Backplane Slot Locations ........................9 3. INSTALLING THE MOTHERBOARD Installing Expansion Boards ......................... 11 Preparation............................11 Plugging an expansion board......................11 Installing Disk Drives ........................... 13 Preparation............................13 Installing Disk Drives ........................13 Installing/Removing a fan and filter..................... 15 FA-UNIT-F6BE/2U...
  • Page 5 Installing the rack mount bracket......................15 Installation conditions ...........................16 4. CONNECTORS Power Supply ............................17 Backplane power supply connectors....................17 HDD/FDD power supply connectors.....................17 Switches and LEDs..........................18 USB Connector ............................19 Power Control Cable ..........................20 5. SYSTEM REFERENCE Specification ............................21 FA-UNIT-F6BE/2U...
  • Page 6: Before Using The Product

    Equipped with a power switch, reset switch, and USB connectors at the front. Equipped with a built-in cooling fan. The dustproof filter and cooling fan can be replaced externally. These fans can easily be replaced externally, without removing the top cover. Key-lockable drive cover preventing unauthorized access to switches and drives. FA-UNIT-F6BE/2U...
  • Page 7: Configuration

    On the front panel, it has the power ON/OFF switch, power LED, HDD access LED, reset switch, and two USB connectors. The SBC, CPU cooler, and expansion boards may not be installed depending on their combination. For details, contact General Information Services of CONTEC. Available Replaceable Parts for Maintenance POW300X...
  • Page 8: Customer Support

    You can download updated driver software and differential files as well as sample programs available in several languages. Note! For product information Contact your retailer if you have any technical question about a CONTEC product or need its price, delivery time, or estimate information. Limited One-Year Warranty CONTEC products are warranted by CONTEC CO., LTD.
  • Page 9: Safety Precautions

    Operation of this equipment in a residential area is likely to cause harmful interference at his own expense. WARNING TO USER Change or modifications not expressly approved the manufacturer can void the user's authority to operate this equipment. FA-UNIT-F6BE/2U...
  • Page 10: Handling Precautions

    Even when using the product continuously, be sure to read the manual and understand the contents. Do not modify the product. CONTEC will bear no responsibility for any problems, etc., resulting from modifying this product. Regardless of the foregoing statements, CONTEC is not liable for any damages whatsoever (including damages for loss of business profits) arising out of the use or inability to use this CONTEC product or the information contained herein.
  • Page 11: Environment

    (2) Store the package at room temperature at a place free from direct sunlight, moisture, shock, vibration, magnetism, and static electricity. Disposal When disposing of the product, follow the disposal procedures stipulated under the relevant laws and municipal ordinances. FA-UNIT-F6BE/2U...
  • Page 12: Name Of Each Part And Dimensions Diagram

    Drive cover Key lock Figure 2.1. Front Side View POWER switch POWER LED RESET USB port Reset switch HDD access LED Figure 2.1. Front Side View (Inner Side of Drive Cover) Rear Side View Figure 2.3. Rear Side View FA-UNIT-F6BE/2U...
  • Page 13: Dimensions

    2. Name of Each Part and Dimensions Diagram Dimensions 10-M4(Maximum tapping length : 6mm) (Including the opposite face) 482.6 44.5 [mm] Figure 2.4. Dimensions FA-UNIT-F6BE/2U...
  • Page 14: Backplane Slot Locations

    70.9 mm, limiting the CPU cooler height from the component side to about 60 mm. For details, contact General Information Services of CONTEC. Please remove a short pin of CN1 when you use the power supply control cable.
  • Page 15 2. Name of Each Part and Dimensions Diagram FA-UNIT-F6BE/2U...
  • Page 16: Installing The Motherboard

    (2) Pull the power plug of the unit from the wall outlet. Plugging an expansion board (1) Remove the screws fastening the top cover, then remove the cover. When loosening the screws, use a screwdriver that fits well in the their slots. (2) Remove a shadow bay over the fan. FA-UNIT-F6BE/2U...
  • Page 17 (5) Put the backplane unit back in place and connect the power cable to the ATX power connector on the backplane. When the SBC in use is a CONTEC product, remove the short pin of CN1 and then connect the SBC to the CN2 connector on the backplane using the attached power control cable.
  • Page 18: Installing Disk Drives

    (1) Remove the screws fastening the top cover, then remove the cover. When loosening the screws, use the appropriate type of screwdriver that fits the screw head. (2) Remove the drive fixing bracket and install drives. Connect the cables and fix them to the original position of the chassis. FA-UNIT-F6BE/2U...
  • Page 19 3. Installing the Motherboard (3) Put the cover back in place and fasten it switch the screws. FA-UNIT-F6BE/2U...
  • Page 20: Installing/Removing A Fan And Filter

    Filter Fan cover Figure 3.1. Installing/Removing a filter Relay connector Figure 3.2. Installing/Removing a fan Installing the rack mount bracket Installing the attached bracket enables rack mount. Figure 3.3. Installing the rack mount bracket FA-UNIT-F6BE/2U...
  • Page 21: Installation Conditions

    3. Installing the Motherboard Installation conditions To prevent a temperature rise, install this chassis at a distance of at least 50mm from obstacles such as walls. [mm] Figure 3.4. Installation conditions FA-UNIT-F6BE/2U...
  • Page 22: Connectors

    HDD/FDD power supply connectors 1. 12V YELLOW 2. GND BLACK To HDD or CD-ROM 3. GND BLACK 4. +5V 1. 12V YELLOW 2. GND BLACK To 3.5 inch FDD 3. GND BLACK 4. +5V Figure 4.2. HDD/FDD Power Supply Connectors FA-UNIT-F6BE/2U...
  • Page 23: Switches And Leds

    These switches and LEDs operate with their respective connector cables connected to the corresponding connectors on the SBC(CPU board). (1)Power SW White Black (2)Power LED Green(+) Black (3)HDD LED Red (+) Black (4)Reset SW Yellow Black Figure 4.3. Switch and LED Connector Cables FA-UNIT-F6BE/2U...
  • Page 24: Usb Connector

    USB internal connection connector. (CHASSIS GND) Pin 10 (GND) Pin 8 (USBP2+) Pin 6 (USBP2-) Pin 4 (VCC2) Pin 2 Pin 9 (N.C.) Pin 7 (GND) Pin 5 (USBP1+) Pin 3 (USBP1-) Pin 1 (VCC1) Figure 4.4. USB Connector Cable FA-UNIT-F6BE/2U...
  • Page 25: Power Control Cable

    This product is bundled with a cable for controlling the ATX power supply. Plug the power control cable into the power control connector (CN2) and the power control connector of the SBC manufactured by CONTEC. For details, refer to the instruction manual for the SBC.
  • Page 26: System Reference

    AC Power Voltage *3 115VAC/230VAC(50/60Hz) (SW selection) Input current 10A(115VAC)/5A(230VAC) AC Outlet Total of +5V and +3V shall not exceed the power of 200W. Input voltage range for AC power supply : 90 - 132VAC / 180 - 250VAC FA-UNIT-F6BE/2U...
  • Page 27 - Power supply About 5 years (25°C, 60%, 75% load, official environment) - Cooling Fan About 5 years (25°C, 60%, official environment) - Fan filter About 1 year (25°C, 60%, official environment) FA-UNIT-F6BE/2U...
  • Page 28 3-9-31, Himesato, Nishiyodogawa-ku, Osaka 555-0025, Japan Japanese http://www.contec.co.jp/ English http://www.contec.com/ Chinese http://www.contec.com.cn/ No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO., LTD. [09202006] [11102005] Management No. A-51-136 [09202006_rev2] Parts No. LYFP772...