Download Print this page

Doorphone Installation Position; Installing The Doorphone; Installing The Power Supply Unit; Main Monitor Installation Position - Panasonic VL-SWD501AZ Installation Manual

Wireless video intercom system

Advertisement

Doorphone installation position

■ Installation height and area visible by the camera lens
You can use the [Wide/Zoom settings] setting on the main monitor to select the area that
is visible when a visitor calls; available settings are [Wide], [Zoom], and [All] (entire image
display). (Default setting: [Wide])
● The following values are for when the doorphone is installed in the standard position
(the centre of the doorphone's height is approximately 1,450 mm) and at a distance of
approximately 500 mm from the camera lens.
When set to wide (default)
Image displayed on
(Units: mm)
main monitor:
Image range
Approx. 95°
Approx. 2,000
Centre of
View when looking
doorphone
from above
Approx. 1,100
Approx. 500
Approx. 1,450
Approx. 500
Approx. 170°
Approx. 900
When set to zoom
Image displayed on
main monitor:
Displays a portion of the wide image at 2 times the size.
● Because a digital zoom is used, the image quality of zoom
display is lower than that of wide display or entire image display.
● You can use the main monitor's [Zoom position settings] setting to select the desired area
visible when zooming. Refer to the following and configure the main monitor.
Up and down
Left and right (when looking from above)
(Units: mm)
(Units: mm)
Up
Left
Image range
Approx. 2,050
Approx. 45°
Centre of
Approx. 550
Image range:
doorphone
Approx. 900
Approx. 500
Approx. 85°
Approx. 170°
Approx. 500
Approx. 1,500
Approx. 1,450
Centre (default)
Centre (default)
Image range:
Approx. 45°
Image range
Approx. 900
Centre of
Approx. 1,650
doorphone
Approx. 400
Approx. 500
Approx. 1,450
Approx. 500
Approx. 1,250
Approx. 85°
Down
Right
Approx. 45°
Image range
Centre of
doorphone
Approx. 1,400
Approx. 550
Approx. 500
Approx. 1,450
Approx. 500
Approx. 85°
Approx. 170°
Approx. 850
Entire image display
The area above and below the wide image is visible.
(Units: mm)
Image displayed on
Image range
main monitor:
Approx. 2,250
Approx. 115°
Centre of
View when looking
doorphone
from above
Approx. 1,600
Approx. 500
Approx. 1,450
Approx. 170°
Approx. 500
Approx. 650

Installing the doorphone

Important:
● On the bottom surface of the doorphone and the mounting base, there are holes to allow water
to drain. Do not cover them up when installing.
● When existing wiring (such as chime wires) is used:
- It may contain AC voltage that may cause electric shock and/or damage the product.
- Never use the following types of wiring. Consult a qualified technician/dealer.
VL-V554BX
1
1
Attach the mounting base to the wall securely.
Screws (accessory) × 2
Mounting base
(accessory)
Knockout hole
83.5 mm
Wall
Wire (locally procured)
● Install the mounting base on a vertical flat wall.
*1 Only open the knockout holes as
required for the wiring.
2
Use a hex wrench (accessory) to loosen screw A and remove the front panel of the door-
phone.
Front panel
Screw A
3
Connect the wires.
<Rear view>
Terminal for the
Terminal for the electric
main monitor
lock
●Recommended torque:
0.5 N·m {5.1 kgf·cm}
●Maximum torque:
0.7 N·m {7.1 kgf·cm}
3-1 Loosen the screws.
3-2 Push in the wires to the terminal connectors (non-polar), then tighten the screws.
4
4
Attach the doorphone to the mounting
Attach the doorphone to the flush mounting
base.
box.
Image range:
Approx. 900
Screws (accessory) × 4
Screws (accessory) × 4
5
Attach the name plate to the doorphone and use screw A to secure the front panel.
● Write the name on the name plate as needed.
Name plate
(accessory)
Screw A

Installing the power supply unit

About the installation location
● The AC cable plug is used as the main disconnect device. Ensure that the power outlet is
installed near the product and is easily accessible.
● A readily accessible disconnect device shall be incorporated external to the equipment.
- External disconnect device must be certified and have a creepage and clearance distance
of 3 mm or more.
Precautions for wiring
● Make sure that the power supply unit is unplugged before performing any wiring work.
VL-V554UBX
● Always connect AC or DC cables to the appropriate connector or connection terminal.
● To prevent the DC cable from disconnecting and to prevent electric shock, secure the DC
Install the flush mounting box in the
cable using the cable binder (accessory) and attach the cable cover.
wall.
Flush mounting box (accessory)
How to connect the AC cable and DC cable
100 mm
Connect the power supply unit (accessory), the AC cable (accessory), and a DC
*1
cable (locally procured).
1
Strip the DC cable as follows:
151 mm
<DC cable>
25 mm
37 mm
7 mm
2
Remove the screw (B) and then remove
the cable cover (A).
3
Connect the AC cable (accessory) to the AC
IN connector on the top of the power supply
unit. Next, connect the DC cable (locally
procured) to the DC OUT terminal on the
bottom of the power supply unit, and then
secure the wires by tightening the screws.
2 mm hex wrench
(accessory)
● Recommended torque: 0.45 N·m {4.6 kgf·cm}
<Front view>
AC cable
Screws
DC cable
*1
Cable binder (accessory)
4
Use the cable binder (accessory) to secure
the DC cable (double-coated area) to the
power supply unit.
5
Attach the power supply unit to the wall.
(
"Wall mounting", below)
6
Make sure to replace the cable cover (A).
Attach the power supply unit to the wall securely.
Screws
(accessory) × 2
● Recommended torque:
0.35 N·m {3.6 kgf·cm}

Main monitor installation position

About the installation position of the main monitor and mounting bracket
● Place the main monitor in a location that your eyes are the same height as the centre
of the display.
● For the following reasons, leave at least 20 cm of space
above, below, and to the left and right sides of the main
monitor:
- To prevent malfunction and sound cutting out
- T o ensure SD cards can be inserted and removed,
and to make sure the reset button can be used
( t he SD card slot is on the side of the main monitor;
the reset button is on the bottom)
● After deciding where to install the main monitor, attach
the mounting bracket in the location shown on the
right.
Power supply unit (with cable cover
removed)
<Top view>
Installing the main monitor
AC IN connector
<Bottom view>
1
Attach the mounting bracket to the wall
DC cable
securely.
binder hole
● Install the mounting bracket on a vertical
DC OUT terminal
flat wall.
CAUTION
Insert the cables firmly all the way
into the connector and terminal.
2
Connect the DC cable and wires.
If the cables are not inserted all
the way, heat may be generated.
● Connect the wires correctly according to "Wiring schematic
diagram".
*1 Make sure that there are no bare wires
exposed outside the product.
How to connect the DC cable:
A Remove screw A and then remove the
terminal cover.
B Loosen screw B and push in the wires of
the DC cable to the terminal connectors
(non-polar), then tighten the screws.
● Recommended torque:
0.8 N·m {8.2 kgf·cm}
Bare wire at tip
12 mm
Screw (B)
C Use the cable binder (accessory) to
Cable cover (A)
secure the DC cable (double-coated
area) to the main monitor.
D Make sure to replace the terminal cover.
Wall mounting
3
Mount the main monitor to the mounting bracket.
3-1 Line up the tab on the bottom of the bracket with the groove on the main monitor (A).
3-2 L ine up the tab on the top of the bracket with the groove on the main monitor, and
push the main monitor down until it is secure (B).
Wall
Notes about electrical wiring
Make sure not to pinch the wires (as shown to the
right) on the mounting bracket when installing.
● Do not forcibly attach to the mounting bracket.
20 cm
SD card
slot
Reset button
20 cm
Main monitor
installation position
Mounting bracket
Vertical, flat wall
Hole in wall
60
83.5
7
Screws
50
(accessory)
(Units: mm)
Screw A
How to make wiring connections:
While pressing on the button with a point-
ed object such as a screwdriver, insert
the wire into the terminal connector. (To
Screw B
disconnect a wire, while pressing on the
button, pull out the wire.)
Terminal Button
Bare wire at tip
32 mm
9 mm
Cable binder
(accessory)
Wiring from
doorphone
Important:
Do not connect the power cable.
(Damage may occur.)
Wall

Advertisement

loading

This manual is also suitable for:

Vl-swd501uaz