Introduction to the RP-Series Fireplace

The complete system will require a firebox, a power vent termination, an
electrical control panel, and a vent system. There are 3 different power
vent terminations available depending on your installation requirements.
Each power vent requires a control cable to be installed between the
power vent and the control panel. Review the installation sequence
for general information on preparing for a successful installation of
your fireplace. The RP-Series fireplace is not intended to be used as a
primary heat source and should not be connected and operated with
a thermostat switch.
PVVEX58-300
PVVEX58-300
Vertical Power Vent
Vertical Power Vent
PVHEX58-300
PVHEX58-300
Horizontal Power Vent
Horizontal Power Vent
PVHFL58-300
PVHFL58-300
Horizontal Power Vent
Horizontal Power Vent
Flush / Louvered
Flush Louvered
RP620
RP620 Fireplace
Fireplace
Light Wiring
Light Wiring
(not supplied)
(not supplied)
Steel stud kit
Steel Stud Kit
(supplied)
(Supplied)
Non-Combustible
Non-combustible
Wall Board Facing
(supplied)
wall board
(supplied)
XG0777 - 180525
PVHIN58-300
PVHIN58-40
TMHIN58-40
PVHIN58-300
Horizontal Flush
Inline Power Vent
Inline Power Vent
Horozontal flush
Termination
termination
Appropriate Montigo Venting
Appropriate venting components 5"x8"
Components 5" x 8"
Power vent control cable (not supplied,
Power Vent Control Cable
(Not supplied. Order required
order required length from dealer)
length from your Montigo Dealer)
Fireplace light switch or dimmer
Fireplace Light
(not supplied)
Switch or Dimmer
(not supplied)
Control panel
Control Panel
Wall Switch
Wall switch On/Off (not supplied)
On/Off
(not supplied)
20' low voltage wire supplied
20' low voltage wire supplied
115 VAC 60Hz supply
115 VAC 60 Hz
supply from
from distribution panel
distribution panel
Control box cable 30'
Control Box Cable
supplied standard
30' supplied standard

Installation Checklist

Install location:
The RP-Series fireplace may be installed in any location that maintains
proper clearances to air conditioning ducts, electrical wiring, and
plumbing. Safety, as well as efficiency of operation, must be considered
when selecting the fireplace location. Try to select a location that does
not interfere with room traffic, has adequate ventilation, and offers an
accessible pathway for Power Vent installation.
Basic Operation:
The gas control components of this fireplace are located in the bottom
of the firebox below the burner system. All models are supplied with a
Honeywell smart valve gas control and do NOT have a variable flame
control. A differential pressure switch is located at the bottom of the
firebox monitors airflow and controls the gas valve. A thermal switch
located on the top of the firebox acts as a secondary safety system
and shuts down the fireplace in the event that normal operating
temperatures exceeded. These components communicate with the
electrical control panel through a six conductor cable supplied with
the fireplace.
To operate the fireplace, Montigo supplies 20' of low voltage wire
from the electrical control panel. Connect the two wire harnesses to a
standard single pole ON/OFF switch to the location of your choice. You
may extend these wires up to 100' in length with a wire of equal quality.
This fireplace is equipped with lights which need to be wired through
a wall switch or dimmer circuit as shown in the schematic.
ON/OFF control of this appliance can also be performed using an
optional remote control available from your Montigo dealer.
Fuel Type
Verify that your fireplace is compatible with your available gas type.
Natural Gas or Propane shown by "N" or "L" in your model number
on rating plate.
• Installation and repairs should be done by a qualified contractor
and must conform to:
• Installations in Canada must conform to the local codes or in the
absence of local codes to the current version of Natural Gas and
Propane Installation Code, CSA B149. Electrical Installations must
conform to the local codes or, in the absence of local codes, to
the current version of Canadian Electrical Code, CSA C22.1.1
• Installations in the USA must conform to the local codes or in the
absence of local codes to the current version of National Fuel
Gas Code, ANSI Z223.1/NFPA 54. Electrical Installations must
conform to the local codes or, in the absence of local codes, to
the current version of the National Electrical Code, ANSI/NFPA 70.
See Appendix C for installation within the State of Massachusetts.
General
7