Download Print this page

nekos KATO 253 Instruction Manual

Chain actuator force 250n - maximum stroke 360 mm electrical feeding 100-240v, 50/60hz - 24v
Hide thumbs Also See for KATO 253:

Advertisement

Quick Links

KATO 253
MANUALE ISTRUZIONI
ATTUATORE A CATENA
IT
Forza 250N - Corsa massima 360 mm
Alimentazione elettrica 100-240V~ 50/60Hz - 24V
INSTRUCTION MANUAL
CHAIN ACTUATOR
EN
Force 250N - Maximum stroke 360 mm
Electrical feeding 100-240V~ 50/60Hz - 24V
BETRIEBSANLEITUNG
KETTENANTRIEB
DE
Kraft 250N - Maximalhub 360 mm
Spannungsversorgung 100-240V~ 50/60Hz - 24V
4420052 - Rev 1710
nekos products have been manufactured in accordance with safety standards and conforms to the
stipulations of current standards in force.
When correctly assembled, installed and used according to the present instructions, they will not
generate any danger for persons, animals or items.
Symbols used in the manual
This indication draw the attention about potential dangers for
DANGER
safety and health of peoples and animals.
INFORMATION
This information give further suggestions.
This indication draw the attention about potential dangers for
ATTENTION
the product itself.
This indication draw the attention about potential damages to
WARNING
goods.
ENVIRONMENTAL
Environmental indication draw the attention about potential
INSTRUCTION
dangers for the environment.
English ................................................................................................................... 14
1. Security rules ............................................................................................................................ 14
2. Formulas and recommendations for installation ...................................................................... 15
3. Technical information about function ........................................................................................ 16
4. Manufacture and applicable standards or regulations .............................................................. 16
5. Technical data .......................................................................................................................... 16
6. Id plate and marking data ......................................................................................................... 17
7. Electrical power supply ............................................................................................................. 17
8. Instructions for assembly .......................................................................................................... 17
9. Electrical connections ............................................................................................................... 20
10. Programming the actuator ........................................................................................................ 21
11. Checking for correct assembly ................................................................................................. 21
12. Emergency manoeuvres, maintenance or cleaning .................................................................. 21
13. Troubleshooting ........................................................................................................................ 22
14. Environmental protection .......................................................................................................... 22
15. Certificate of guarantee ............................................................................................................ 22
16. Declaration of incorporation (for a partly completed machine) and EC declaration of
conformity ................................................................................................................................. 34
3

Advertisement

loading

Summary of Contents for nekos KATO 253

  • Page 1: Table Of Contents

    When correctly assembled, installed and used according to the present instructions, they will not generate any danger for persons, animals or items.
  • Page 2: English

    MANDATORY RISK ANALYSIS AND PROTECTION MEASURES 2. FORMULAS AND RECOMMENDATIONS FOR INSTALLATION The Nekos electrical actuators comply with the Machinery Directive (2006/42/EC), Standard IEC 60335- 2-103 (Particular requirements for drives for gates, doors and windows) and other directives and 2.1.
  • Page 3: Technical Information About Function

    Electrical connections must conform to regulations in force for the design and set up of electrical equipment. 1. KATO 253 230V~: runs on grid tension of 100-240V~, 50/60Hz, with a three wire cable To ensure efficient separation from the grid, an approved type of bipolar “dead-man”...
  • Page 4 Actuator specifications must be sufficient for movement of the window without C. Apply the template onto the window frame (fixed part), taking care to ensure that the axis of the template coincides with centrepoint X traced earlier (Fig.4). Attention: for non coplanar window encountering any obstacle.
  • Page 5: Electrical Connections

    NEKOS patent allows rapid unhooking of the chain. To perform this operation, proceed as follows: 1. Unhook the flap of the quick hook locking the chain terminal to the bracket.
  • Page 6: Troubleshooting

    The device is mainly made from the following materials: aluminium, zinc, iron, plastic of Type : 24 V : KATO 253 - KATO - KIMO - KATO 305 various type, cuprum. Dispose materials in conformity with local regulations about KATO SYNCRO - KATO 305 SYNCRO removal.
  • Page 7 NEKOS S.r.l. - Via Capitoni, 7/5 36064 Mason Vicentino (VI) – ITALY +39 0424 411011 – Fax +39 0424 411013 www.nekos.it info@nekos.it...