Rav-Gm1101At , Gm1401At - Toshiba RAV-GM561ATP-E Service Manual

Outdoor unit, digital inverter
Hide thumbs Also See for RAV-GM561ATP-E:
Table of Contents

Advertisement

13-2. RAV-GM1104AT
No.
Part name
Common
1
procedure
Be sure to put on the gloves at working time;
otherwise an injury may be caused by a part,
etc.
1. Detachment
2. Attachment
Using bundling band on the market, be sure to
fix the power wire and indoor/outdoor
connecting wire along the crossover pipe so that
they do not come to contact with the
compressor, valve at gas side, pipe at gas side
and discharge pipe.
, GM1401AT
P
*
*
Procedure
CAUTION
1) Stop operation of the air conditioner and then
turn off switch of the breaker.
2) Remove the front panel.
(Hexagonal screw Ø4 × 10, 2 pcs.)
∗ After removing screws, remove the front
panel while pulling it downward.
3) Remove the power wire and indoor/outdoor
connecting wire from the cord clamp and the
terminals.
4) Remove the top plate.
(Hexagonal screw Ø4 × 10, 5 pcs.)
1) Attach the top plate.
(Hexagonal screw Ø4 × 10, 5 pcs.)
In this time, insert the fin guard of rear side
between the top plate and the heat exchanger
(Rear side).
2) Connect the power supply wire and the
indoor/outdoor connecting wire to the terminal
and fix it with cord clamp.
CAUTION
3) Attach the front panel.
(Hexagonal screw Ø4 × 10, 2 pcs.)
P
*
*
- 104 -
FILE NO. SVM-18043
Remarks
Insert the fin guard of rear side between
the top plate and the heat exchanger
(at rear side).
Front panel
Top plate

Hide quick links: