3-16. Wiring Instructions for Inter-Unit Connections

(a) Insert the inter-unit wiring (according to local
codes) into the through-the-wall PVC pipe. Run
the wiring toward the indoor side allowing approx.
5". to extend from the wall face. (Fig. 3-44)
2 2 2 2 2
CAUTION
K
(b) Remove the side cover and the metallic cover.
(Fig. 3-45 or 3-46, depending on model.)
(c)
Secure the conduit connector to the chassis with
a lock nut. (Fig. 3-45 or 3-46)
(d) Give some play to the inter-unit wiring from the
outdoor unit to the corresponding terminals on the
terminal plate.
CAUTION
(e) Secure the metallic cover with its screw. Then
replace the side cover.
KH2442
Look nut
Never fix the wiring by any
means before the indoor
unit is fully seated on the
rear panel.
Be sure to refer to the
wiring system diagram
label inside the metallic
cover and carry out the
correct field wiring.
Wrong wiring can cause
the unit to malfunction.
Check local electrical
codes and any specified
wiring instructions or
limitations.
Lock
Metallic cover
nut
Plastic cover
Power line
Grounding
line
Elbow
conduit
Fig. 3-45
KH2442
Rear
panel
Wiring
KH3642
Connector
KH3642
Screw
Lock
nut
Connector
0968_T_I
28
S4359146
Plastic
cover
5"
1362_T_I
Wall fixture
Wall
Wiring
5"
Fig. 3-44
1363_T_I
Metallic cover
Side cover
Fig. 3-46
Wall
1395_T_I