Sanyo C2462R Technical Data & Service Manual page 26

Split system air conditioner
Hide thumbs Also See for C2462R:
Table of Contents

Advertisement

8. INSTALLATION INSTRUCTIONS
Wind Shield for "CL" Model
IMPORTANT
It is recommended to use wind shields for "CL" model
(Fig. 5b). "CL" model is designed to use in low outdoor
temperature conditions.
General
When the outdoor unit is installed in a position exposed
to strong wind (like seasonal winds with low air tempera-
ture in winter), a suitable wind shield must be installed
on the outdoor unit.
This unit is designed so that the fan of the outdoor unit
runs at low speed when the air conditioner is operated at
low outdoor air temperatures. When the outdoor unit is
exposed to strong wind, the system pressure drops
because of the freeze protector.
For outer dimensions of the wind shield, see Fig. 5c.
Wind shield
(air discharge side)
Recommended outer dimensions of wind shield
(field supply)
1-1/16"
9-27/32"
– 26 –
Front
Fig. 5b
21-13/16"
9-27/32"
21-13/16"
CL2462R
Fig. 5c
SM830092
5-5/32"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl2462rKs2462r

Table of Contents