8. INSTALLATION INSTRUCTIONS
2)
Selecting the Installation Site
Indoor Unit
AVOID:
areas where leakage of flammable gas may
be expected.
places where large amounts of oil mist
exist. (Fig. 2)
direct sunlight.
locations near heat sources which may
affect performance of the unit.
locations where external air may enter the
room directly. This may cause "sweating"
on the air discharge ports, causing them to
spray or drip. (Fig. 3)
locations where the remote control unit will
be splashed with water or affected by
dampness or humidity.
DO:
select an appropriate position from which
every corner of the room can be uniformly
air-conditioned.
select a location that will hold weight of the
unit.
select a location where the tubing and drain
pipe have the shortest run to the outside.
(Fig. 2)
allow room for operation and maintenance
as well as unrestricted air flow around the
unit. (Fig. 3a and 3b)
Install the unit within the maximum
elevation difference above or below the
outdoor unit and within a total tubing length
from the outdoor unit as detailed in Table 1
and Fig. 1 on the previous page.
Indoor unit
Outside drainage
6 inches
min.
CAUTION
For stable operation of
the air conditioner, do
not install wall-mounted
type indoor units less
than 5 ft. from floor
level.
– 24 –
Drain hose
2203_M_S
Fig. 2
6 inches min.
6 inches
min.
INDOOR UNIT
Front View
2204_M_S
Fig. 3a
Indoor Unit
Minimum height
from floor level
5 ft.
Floor level
Fig. 3b
SM830092
Wall
2205_M_S