Installation Preparation

Installation Considerations

"
"
"
(190)
(190)
18"
18"
18"
(457)
(457)
(457)
* 30" (762) min.
* 30" (762) min.
* 30" (762) min.
40" (1,016) max.
40" (1,016) max.
40" (1,016) max.
to Cooking Surface
to Cooking Surface
to Cooking Surface
* Follow cooking appliance manufacturer's
recommendations
Hood Width
The hood width should be no less than the width of the
cooking surface. For proper performance, the housing must
cover the entire cooking surface.
For proper performance, the hood must be centered
horizontally above the cooking surface.
Distance From Cooking Surface
Hood installation height above a cooktop, rangetop or
range can vary. The installation height ranges from a
minimum height of 30'' (762 mm) to a maximum height of
40'' (1,016 mm); however, it is necessary to follow the
cooking appliance manufacturer's installation instructions
for proper hood height (Figure 2).
Installation Instructions
Electrical
Zone
Cooking
Surface
inches (millimeters)
Figure 2: Typical Hood Installation
NOTICE: The hood could incur some damage from heat if
a THERMADOR PROFESSIONAL
rangetop is operated with multiple burners at high settings
under a hood that is installed at minimum clearances.
Unit Weight
When calculating the load for the housing support system,
be sure to consider the weight of the ventilation unit.
Hood, Filters, Grease Trays, and Spacers 104 lb (47 kg)
Integral Blower Model VTN1090
IMPORTANT:
The supplied weights address only the ventilation unit
and blower. Installer must account for weight of any
materials of construction when calculating the total dead
weight load of installation, including but not limited to:
wall, tile, mortar, plaster, brick, finishes, partitions, and
other similarly incorporated architectural and structural
items. It is the responsibility of the owner and the installer
to determine if additional requirements and/or standards
apply to specific installations.
Blower Motors
Integral, in-line and remote blowers are available through
your authorized THERMADOR
information, visit the Find a Dealer section of our website at
www.thermador.com.
The blower will vary in size and is dictated by the cooking
surface, the volume of air that needs to be moved and the
length of the duct run. Refer to the Ventilation Planning
Guide for detailed blower motor information.

Electrical Requirements

The unit requires a 120V AC, 60Hz. 20A branch circuit.
The hood should only be connected to a dedicated circuit
(with ground) that has been installed according to relevant
regulations.
®
series range or