CM-550SK-V2 WATERPROOF KEYPAD
INSTA L L AT I O N I NST RU CTI ONS
Wiegand Reader
Stand alone for single door (factory default setting)
8.9 Setting Keypad Transmission Format
Setting keypad transmission format
Note: Keypad transmission format is 0 1 2, factory default is 0; not affected by resetting to factory default.

8.10 Setting Alarm Time

Setting alarm time
Note: Factory default is 1 minute, not affected by resetting to factory default.
8.11 Setting Safe Mode
Normal mode (factory default)
Lock out mode
Note: If an invalid card or wrong PIN is input 10 times in 10 minutes, user will be locked out for 10 minutes.
Alarm mode
Note: If an invalid card or wrong PIN is input 10 times in 10 minutes, external alarm and built-in buzzer will sound.
8.12 User Optional Setting
Setting keypad tone OFF or ON
8.13 Setting Keypad Backlight
Disable keypad backlight
Enable keypad backlight
Automatic mode (factory default setting)
8.14 Setting LED Light (Standby Status)
Disable LED light
Flash LED light (factory default setting)
Page 6 of 11
Press 31, 0, #
Press 31, 1, #
Press 33, 0-2, #
Press 34, 1-3, #
Press 35, 0, #
Press 35, 1, #
Press 35, 2, #
Press 41, 0, # OFF
Press 41, 1, # ON (Default)
Press 42, 0, #
Press 42, 1, #
Press 42, 2, #, Keypad will illuminate when a key is pressed.
Press 43, 0, #
Press 43, 1, #