Scotsman DXN 207 Service Manual page 24

Electronic counter cubelet ice dispenser
Table of Contents

Advertisement

Page 23
1. Close the water tap first; through the green
ON/OFF button turn OFF the machine; wait 30
seconds then switch ON again.
2.
Machine starts to purge the water from the
reservoir, wait 2 minutes, then extract the upper
section of the front panel, unscrew the two
fastening screws and remove the top panel, the
machine will automatically switch OFF.
3.
In a carafe, prepare 500 ml of warm water
(40-50°C) and 15 ml of Scotsman Sanitizing
product and wait at least 10 minutes.
4.
Open the plug of the funnel and pour the
sanitizing solution in the reservoir.
5. Unscrew the two fastening screws and remove
the bin cover
6.
Lift up the ice level control and its bracket
from its housing and carefully stand it on the
frame of the unit.
Remove ice, distribution vane and steel bottom
from the storage bin.